SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:ea83c489-8625-4f3f-8900-377082862bd0"
 

Search: onr:"swepub:oai:lup.lub.lu.se:ea83c489-8625-4f3f-8900-377082862bd0" > High-resolution map...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

High-resolution maps of magnetization transfer with inherent correction for RF inhomogeneity and T1 relaxation obtained from 3D FLASH MRI

Helms, Gunther (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Dathe, Henning (author)
Kallenberg, Kai (author)
show more...
Dechent, Peter (author)
show less...
 (creator_code:org_t)
2008-11-24
2008
English.
In: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 60:6, s. 1396-1407
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • An empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH, introducing a novel semiquantitative parameter for MT, the percentage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T1 weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging at 3T was based on nonselective sagittal 3D-FLASH at 1.25mm isotropic resolution using partial acquisition techniques (TR/TE/flipangle = 25ms/4.9ms/5° or 11ms/4.9ms/15° for the T1 reference). A 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540° flip angle. The MT saturation maps showed an excellent contrast in the brain due to clearly separated distributions for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15°, TR/T1<<1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T1 relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Helms, Gunther
Dathe, Henning
Kallenberg, Kai
Dechent, Peter
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Image Pr ...
Articles in the publication
Magnetic Resonan ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view