SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:f821f2e5-849c-44ef-8567-6527ed6ef203"
 

Search: onr:"swepub:oai:lup.lub.lu.se:f821f2e5-849c-44ef-8567-6527ed6ef203" > Feasibility Study o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Feasibility Study of Gel Filtration as a Separation Method for Blood Serum Proteins in Combination with PIXE Analysis

Pallon, Jan (author)
Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Pakarinen, Pirjo (author)
Malmqvist, Klas (author)
Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
show more...
Akselsson, Roland (author)
Lund University,Lunds universitet,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
show less...
 (creator_code:org_t)
1987
1987
English.
In: Biological Trace Element Research. - 1559-0720. ; 12:1, s. 401-409
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The combination between a protein separation technique and the PIXE method has a great potential for large surveys, including thousands of samples, in which multielemental analysis is required. Gel filtration with a Sephadex G-200 gel and a TRIS-acetate buffer was used for separating proteins in human serum. The fractions were doped with an yttrium/vanadium standard and then concentrated and pipeted onto Kimfol™ backing foils. Using the PIXE technique, the distributions of Fe, Cu, Zn, and Se, with respect to molecular size, were found, indicating binding to specific proteins. Sulfur and phosphorus were found to correlate well with the protein content measured by UV-absorption at 280 nm. Further developments and tests on the protein separation technique is required, taking restrictions imposed by the PIXE method into consideration.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Produktionsteknik, arbetsvetenskap och ergonomi (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Production Engineering, Human Work Science and Ergonomics (hsv//eng)
NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Keyword

metal-binding proteins
trace elements
protein separation
PIXE
work environmental health
human serum

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Pallon, Jan
Pakarinen, Pirjo
Malmqvist, Klas
Akselsson, Rolan ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
and Production Engin ...
NATURAL SCIENCES
NATURAL SCIENCES
and Physical Science ...
and Subatomic Physic ...
Articles in the publication
Biological Trace ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view