SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:fa133e06-8e23-45d6-a554-da9ec41f4cee"
 

Search: onr:"swepub:oai:lup.lub.lu.se:fa133e06-8e23-45d6-a554-da9ec41f4cee" > Emissions from Fire...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Blomqvist, PerRISE,Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,SP Sveriges tekniska forskningsinstitut / Brandteknik, forskning (BRf ) (author)

Emissions from Fires Part II: Simulated Room Fires

  • Article/chapterEnglish2004

Publisher, publication year, extent ...

  • 2004

Numbers

  • LIBRIS-ID:oai:lup.lub.lu.se:fa133e06-8e23-45d6-a554-da9ec41f4cee
  • https://lup.lub.lu.se/record/790545URI
  • https://doi.org/10.1023/B:FIRE.0000003316.63475.16DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-5872URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:art swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • Detailed quantitative characterization of the combustion gases from a series of room fires is reported in this article. Three simulated room fires were conducted with a test room containing a typical domestic fuel load of furniture including a TV-set. Two types of TV-sets were studied in the experiments, i.e. those containing fire retarded and non-fire retarded enclosure material. The measurement of the combustion gases included inorganic species and various organic species among them polychlorinated and polybrominated dibenzodioxins and furans, and selected brominated flame retardant agents. The detailed quantitative characterization of the combustion gases from the room fires forms a unique source of emission data for fire incidents in buildings. Chlorinated dibenzodioxins and furans were found in the combustion gases from all room tests. No brominated dioxins were found, however brominated furans were found. Further, the results from the room tests indicate that a TV-set treated with brominated flame retardants included in the fire load of a room fire does not necessarily increase the emission of bromine containing organic combustion products. The methodology applied for the sampling and analysis has been described in Part I of this series of articles.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Rosell, LarsRISE,SP – Sveriges Tekniska Forskningsinstitut / Organisk kemi (Kmo) (author)
  • Simonson, MargaretRISE,SP – Sveriges Tekniska Forskningsinstitut / Brandteknik, skydd (BRs ) (author)
  • Avdelningen för BrandteknikInstitutionen för bygg- och miljöteknologi (creator_code:org_t)

Related titles

  • In:Fire Technology40:1, s. 59-730015-2684

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Blomqvist, Per
Rosell, Lars
Simonson, Margar ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Other Civil Engi ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Building Technol ...
Articles in the publication
Fire Technology
By the university
Lund University
RISE

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view