SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:fc741d11-16f2-450c-8a0f-16738f663aa4"
 

Search: onr:"swepub:oai:lup.lub.lu.se:fc741d11-16f2-450c-8a0f-16738f663aa4" > Sensitizing capacit...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Sensitizing capacity and cross-reactivity of phenyl glycidyl ether studied in the guinea-pig maximization test.

Pontén, Ann (author)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Zimerson, Erik (author)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Bruze, Magnus (author)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
 (creator_code:org_t)
Wiley, 2009
2009
English.
In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:2, s. 79-84
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Simultaneous contact allergies to the reactive diluent phenyl glycidyl ether (PGE) and epoxy resins based on diglycidyl ether of bisphenol A (DGEBA) or epoxy resins of the bisphenol F-type have been reported. The latter epoxy resins contain three isomers of diglycidyl ether of bisphenol F (DGEBF). PGE, DGEBA, and DGEBF are chemically similar with respect to the reactive glycidyl group and an aromatic ring, making cross-reactivity one of the possible explanations to simultaneous reactions. AIM: To investigate the sensitizing capacity of PGE and the cross-reactivity of PGE versus the epoxy resin monomers DGEBA and the three DGEBF monomers and vice versa. METHOD: The guinea-pig maximization test. RESULTS: PGE is a strong sensitizer. Induction with DGEBA resulted in a statistically significant number of animals reacting to PGE, but when induced with PGE, the animals did not react significantly to DGEBA. CONCLUSIONS: When the results are applied to humans, it can be assumed that patients sensitized primarily to DGEBA react to PGE, but when sensitized exclusively to PGE, they do not react to DGEBA. Both reactive diluents and epoxy resins should be tested when contact allergy to epoxy resin systems are suspected.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Dermatologi och venereologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dermatology and Venereal Diseases (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Pontén, Ann
Zimerson, Erik
Bruze, Magnus
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dermatology and ...
Articles in the publication
Contact Dermatit ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view