Neurally adjusted ventilatory assist and pressure support ventilation in small species and the impact of instrumental dead space

Jalde, FC (author)
Karolinska Institutet
Almadhoob, AR (author)
Beck, J (author)
show more...
Slutsky, AS (author)
Dunn, MS (author)
Sinderby, C (author)
show less...
 (creator_code:org_t)
2009-11-04
2010
English.
In: Neonatology. - : S. Karger AG. - 1661-7819 .- 1661-7800. ; 97:3, s. 279-285
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • <i>Background:</i> Neurally adjusted ventilatory assist (NAVA) is a pneumatically-independent mode of mechanical ventilation controlled by diaphragm electrical activity (EAdi), and has not yet been implemented in very small species. <i>Objectives:</i> The aims of the study were to evaluate the feasibility of applying NAVA in very small species and to compare this to pressure support ventilation (PSV) in terms of ventilatory efficiency and breathing pattern, and evaluate the impact of instrumental dead space on breathing pattern during both modes. <i>Methods:</i> Nine healthy rats (mean weight 385 ± 4 g) were studied while breathing on PSV or NAVA, at baseline or with added dead space. <i>Results:</i> A clear difference in breathing pattern between NAVA and PSV was observed during both baseline and dead space, where PSV – despite similar EAdi and tidal volume as during NAVA – caused shortened inspiratory time (p < 0.05) and increased the respiratory rate (p < 0.05). A higher minute ventilation (p < 0.05) in order to reach the same arterial CO<sub>2</sub> was observed. Ineffective inspiratory efforts occurred only during PSV and decreased with the dead space. <i>Conclusion:</i> This study demonstrates, in a small group of animals, that NAVA can deliver assist in very small species with a higher efficiency than PSV in terms of eliminating CO<sub>2</sub> for a given minute ventilation.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jalde, FC
Almadhoob, AR
Beck, J
Slutsky, AS
Dunn, MS
Sinderby, C
Articles in the publication
Neonatology
By the university
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view