SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:prod.swepub.kib.ki.se:1958512"
 

Search: onr:"swepub:oai:prod.swepub.kib.ki.se:1958512" > Assessment of the p...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Assessment of the perceptual threshold of touch (PTT) with high-frequency transcutaneous electric nerve stimulation (Hf/TENS) in elderly patients with stroke: a reliability study

Eek, E (author)
Engardt, M (author)
2016-07-01
2003
English.
In: Clinical rehabilitation. - : SAGE Publications. - 0269-2155 .- 1477-0873. ; 17:8, s. 825-834
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: To evaluate the inter-rater reliability and reliability between occasions of assessing the perceptual threshold of touch (PTT) with high-frequency transcutaneous electric nerve stimulation (Hf/TENS) in elderly patients with stroke. Design: A test–retest study of reliability using intraclass correlation coefficient (ICC) and limits of agreement. Setting: Geriatric rehabilitation unit. Subjects: Thirty-two consecutive patients with stroke 3 65 years of age. Main outcome measures: Two-channel current stimulator TENS CEFAR Tempo with four self-adhesive skin electrodes. The stimulator delivered a high-frequency constant current of 40 Hz. The strength of the stimulation was quantifiable and assessed in milliampere (mA). Interventions: The assessments were performed on the hands and feet by two raters. The PTT was identified as the level registered in milliampere (mA) at which the patients perceived a tingling sensation. Results: The ICC values (0.94–0.99) were shown to be good for inter-rater reliability, as well as reliability between occasions. However an additional analysis with limits of agreement showed a high level of agreement for assessment of the hand but a moderate to low agreement for assessment of the foot where some bias was also identified. Clinical acceptable reliability: 3 1 mA for the hand and 3 5 mA for the foot are so far recommended for establishing real differences in clinical measures. Conclusion: Hf/TENS shows an overall high reliability for assessing the PTT of the hand and moderate to low reliability for the foot. Additional research with exclusion of bias is needed to determine the reliability of assessing the foot.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Eek, E
Engardt, M
Articles in the publication
Clinical rehabil ...
By the university
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view