SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:08fe0622-7499-41e9-a7e2-e50b0d21875d"
 

Search: onr:"swepub:oai:research.chalmers.se:08fe0622-7499-41e9-a7e2-e50b0d21875d" > A miniaturized flow...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A miniaturized flow reaction chamber for use in combination with QCM-D sensing

Ohlsson, Gabriel, 1982 (author)
Chalmers tekniska högskola,Chalmers University of Technology
AXELSSON, PAULINE, 1982 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Henry, Joshua, 1978 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Petronis, Sarunas, 1972 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Svedhem, Sofia, 1970 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Kasemo, Bengt Herbert, 1942 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show less...
 (creator_code:org_t)
2010-03-06
2010
English.
In: Microfluidics and Nanofluidics. - : Springer Science and Business Media LLC. - 1613-4990 .- 1613-4982. ; 9:4-5, s. 705-716
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A miniaturized flow chamber for quartz crystal microbalance with dissipation monitoring (QCM-D) has been developed. The main purpose was to reduce the total liquid sample consumption during an experiment, but also to gain advantages with respect to kinetics and mass transport by reducing the boundary diffusion layer. The bottom of the flow chamber is a QCM-D sensor surface, on which a polydimethylsiloxane spacer ring, fabricated onto a poly(methyl methacrylate) lid, is placed symmetrically around the QCM-D electrode (diameter similar to 10 mm). The spacer ring defines the inner chamber height (typically 40-50 mu m) and provides sealing. Through the lid, there are inlet and outlet channels. The typical chamber volume is in the range of 2.5-3.5 mu l (with a 10 mu l dead volume). In flow mode, we have operated the cell at flow rates of 6-50 mu l/min, i.e., volume turnovers of 2-17 per min. As a model system, to test the microcell, the formation of supported phospholipid bilayers on a SiO2 surface was studied. For comparison, the same process was studied in a commercially available QCM-D equipment with significantly larger total volume (by a factor of 20). The decrease in effective sample consumption to produce a bilayer on the sensor surface in the chamber was approximately proportional to the decrease in chamber volume. Smaller volume also reduced the liquid exchange time. Potential improvements of the chamber include further optimization of the flow profile and, in addition, further miniaturization by decreasing the chamber height and the sensor radius.

Subject headings

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Keyword

quartz-crystal microbalance
QCM-D
fabrication
vesicle adsorption
supported
Biosensor
real-time
Boundary layer diffusion
membrane
immersion angle
lipid-bilayers
binding
Miniaturized flow chamber
Supported lipid bilayers
surface-plasmon resonance
cell culture

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view