Analysis of operational data from a district cooling system and its connected buildings

Jangsten, Maria, 1989 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Lindholm, Torbjörn, 1965 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Dalenbäck, Jan-Olof, 1954 (author)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Elsevier BV, 2020
2020
English.
In: Energy. - : Elsevier BV. - 0360-5442. ; 203
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • District cooling systems are likely to become more common as the cooling demands in cities increase. Their performance is often challenged by low temperature differences between the supply and return water, called low delta-T. Few previous studies have investigated low delta-Ts in district cooling systems with heat exchangers separating the distribution system and the connected buildings, which therefore is the objective of this study. The study is based on an analysis of operational data from both district cooling provider and 37 of the connected buildings chilled water systems, collected from the energy transfer stations during spring and summer of 2018. The design delta-T in the district cooling system is 10 °C, while the actual delta-T varies between 6 and 8 °C. The study shows the main causes to the low delta-T are the following: operation in the saturation zone; too low building chilled water return temperature; too low temperature approach of the heat exchanger's supply streams and non-optimized supply temperatures in the buildings. Potential solutions to resolve the low delta-T include adjusting the supply temperature setpoint on the secondary side; restricting the flow on the primary side; providing economic incentives for the district cooling customers and ensuring compliance with the design guidelines.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Temperature approach
Building chilled water system
Low delta-T
Heat exchanger
Energy transfer station
District cooling

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

  • Energy (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jangsten, Maria, ...
Lindholm, Torbjö ...
Dalenbäck, Jan-O ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Mechanical Engin ...
and Energy Engineeri ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Environmental En ...
and Energy Systems
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Building Technol ...
Articles in the publication
Energy
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view