Heat Transfer and Pressure Drop Under Dry and Humid Conditions in Flat-Tube Heat Exchangers With Plain Fins

Haglund Stignor, Caroline (author)
SP Sveriges Tekniska Forskningsinstitut AB
Sundén, Bengt (author)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
Fahlén, Per, 1947 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Stensson, S. (author)
SP Sveriges Tekniska Forskningsinstitut AB
show less...
 (creator_code:org_t)
Informa UK Limited, 2010
2010
English.
In: Heat Transfer Engineering. - : Informa UK Limited. - 0145-7632 .- 1521-0537. ; 31:3, s. 179-192
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Flat-tube heat exchangers could be an interesting alternative to make indirect cooling of display cabinets more energy-efficient. This application involves low air velocities in combination with condensation of water vapor on the air side, so plain fins could be suitable. Two different heat exchangers having flat tubes and plain fins on the air side were evaluated experimentally. One of the heat exchangers had continuous plate fins, and the other had serpentine fins. The performances during dry and wet test conditions were compared and related to theoretical predictions for different assumptions. The influence of air velocity, air humidity, and inclination angle was investigated. The results show that, in most cases, the heat transfer performance is somewhat reduced under wet conditions in comparison with dry test conditions, and that wet heat transfer surfaces lead to an increased pressure drop. At the lower air velocity range that was investigated, the heat exchanger having continuous plate fins drained better than the one with serpentine fins.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Keyword

surfaces

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view