Search: onr:"swepub:oai:research.chalmers.se:3892a16e-f82c-49d8-a7e3-2e9ef1691fb8" >
Microfluidic biosen...
Microfluidic biosensor for the detection of DNA by fluorescence enhancement and the following streptavidin detection by fluorescence quenching
-
- Wang, Jun, 1976 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Aki, Michihiko (author)
- Fujitsu FTP Corporation
-
- Onoshima, Daisuke (author)
- Nagoya University
-
show more...
-
- Arinaga, Kenji (author)
- Fujitsu FTP Corporation
-
- Kaji, Noritada (author)
- Nagoya University,Fujitsu FTP Corporation
-
- Tokeshi, Manabu (author)
- Hokkaido University,Nagoya University
-
- Fujita, Shozo (author)
- Fujitsu FTP Corporation
-
- Yokoyama, Naoki (author)
- Fujitsu FTP Corporation
-
- Baba, Yoshinobu (author)
- Nagoya University,National Institute of Advanced Industrial Science and Technology (AIST)
-
show less...
-
(creator_code:org_t)
- Elsevier BV, 2014
- 2014
- English.
-
In: Biosensors and Bioelectronics. - : Elsevier BV. - 0956-5663 .- 1873-4235. ; 51, s. 280-285
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://research.cha...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- We reported an optical DNA/protein microfluidic sensor which consists of single stranded (ss) DNA-Cy3 probes on gold surface and simple line-shape microfluidic channel. These ssDNA-Cy3 probes with random sequence in bulk solution or on gold surface exhibits fluorescence enhancement after binding with complementary ssDNA (cssDNA) targets. Particularly it did not require complicated design or hairpin-like stem-loop conformation, which made it easier to be made and applied in analytes detection by fluorescence switching techniques. Using ssDNA-cy3 probes attached on gold surface in a microfluidic channel, strong fluorescence enhancement was measured by ssDNA with cssDNA binding or ssDNA with cssDNA-biotin binding. The following introduction of streptavidin resulted in fluorescence quenching (fluorescence decrease) because of the binding of hybridized DNA-biotin with streptavidin. This sensor showed strong affinity and high sensitivity toward the streptavidin, the minimum detectable concentration for streptavidin was 1 pM, equating to an absolute detection limit of 60 amol in this microfluidic channel. Microfluidic channel height and flow rate is optimized to increase surface reaction efficiency and fluorescence switching efficiency. In contrast to previously reported optical molecular beacon approach, this sensor can be used not only for the detection of cssDNA target, but also for the detection of streptavidin. This microfluidic sensor offers the promise of analyzing kinds of molecular targets or immunoreactions.
Subject headings
- NATURVETENSKAP -- Biologi -- Biofysik (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences -- Biophysics (hsv//eng)
Keyword
- probes
- binding proteins
- interrogation
- hybridization
- analysis systems
- sensitive detection
- nucleic-acid
- thiazole orange
- molecular-beacon
- electron-transfer
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database
- By the author/editor
-
Wang, Jun, 1976
-
Aki, Michihiko
-
Onoshima, Daisuk ...
-
Arinaga, Kenji
-
Kaji, Noritada
-
Tokeshi, Manabu
-
show more...
-
Fujita, Shozo
-
Yokoyama, Naoki
-
Baba, Yoshinobu
-
show less...
- About the subject
-
- NATURAL SCIENCES
-
NATURAL SCIENCES
-
and Biological Scien ...
-
and Biophysics
- Articles in the publication
-
Biosensors and B ...
- By the university
-
Chalmers University of Technology