Partial Discharge Measurements under DC Voltages Containing Harmonics Produced by Power Electronic Devices

Romano, Pietro (författare)
Universita degli Studi di Palermo,University of Palermo
Parastar, Amir, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Imburgia, A. (författare)
Universita degli Studi di Palermo,University of Palermo
visa fler...
Blennow, Jörgen, 1966 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Bongiorno, Massimo, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Di Tommaso, A (författare)
Universita degli Studi di Palermo,University of Palermo
Hammarström, Thomas, 1974 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Serdyuk, Yuriy, 1963 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2018
2018
Engelska.
Ingår i: Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP. - 0084-9162. ; 2018-October, s. 558-561
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Partial Discharge (PD) monitoring is one of the main diagnostic instrument to evaluate the reliability of modern electrical transmission and distribution systems. The widespread use of High voltage dc (HVDC) connections increase the demand of voltage source converters (VSCs) which, as a consequence, has brought about new challenges in the field of partial discharge measurements. In fact, the output voltage waveforms generated by AC/DC modular multilevel converters (MMCs) are affected by a significant harmonic content which influences the Partial Discharges (PDs) activity. For this reason, previous research mainly investigated the PD phenomenon on the AC side of the converter. The aim of the present work was to evaluate the PDs behavior applying a voltage waveform containing ripple at the DC side of the converter. At first, a pure DC voltage has been used to stress the tested specimen and then harmonic content has been added by chancing the number of modules of the simulated AC/DC converter. For the different generated waveforms, measurements of PDs have been carried out and a comparison of the different PDs pattern have been made. The effect on the PDs behavior has been also evaluated for different switching frequencies.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

partial discharge
harmonic content
pd pattern
voltage source converter
multilevel converter

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy