SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:5fd01363-7083-44a7-9ab8-52ac648f9d0f"
 

Search: onr:"swepub:oai:research.chalmers.se:5fd01363-7083-44a7-9ab8-52ac648f9d0f" > Icke-azeotropa blan...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Icke-azeotropa blandningar i värmepumpar - Förstudie för fullskaleprojekt

Albert, Ludvig (author)
Chalmers tekniska högskola,Chalmers University of Technology
Berntsson, Thore, 1947 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Högberg, Marine, 1962 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Persson, Lennart, 1943 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show less...
 (creator_code:org_t)
1990
Swedish.
  • Reports (other academic/artistic)
Abstract Subject headings
Close  
  • In cooperation between STAL Refrigeration AB and the Department of Heat and Power Technology, Chalmers University of Technology, an experimental heat pump with a nonazeotropic mixture as working fluid is being prepared. This will be the first full scale plant in Sweden.This report contains the results from a pre-study to thefull scale project. The influence of a non-azeotropic mixture, as compared with a pure fluid on the design of the components in the heat pump, has been analyzed. This study has partly been done with a previously developed computer program, which has been improved. Some supplementary routines have been added to it, and the specific design of the prepared experimental planthas been inserted.The experimental heat pump which is to be used, has a countercurrent evaporator and a crosscurrent condenser. Since the best design for a non-azeotropic mixture is countercurrent, heat exchanger calculations have been done for this type of condenser. Comparisons indicate that a shell and tube heat exchanger with the non-azeotropic mixture on the shell side is highly interesting to investigate practically. The study of the internal heat exchanger shows that the dependence of COP on the degree of superheat before the compressor is slightly larger for a non-azeotropic mixture than for a pure fluid.During this project and also afterwards a dynamic debate onthe environmental effect of "CFCs" has been going on. Theuse of the mixture HCFC22/CFCl14, suggested in this report,will be forbidden in the future. However, it is stillinteresting to study it, since there are more and betterthermodynamic and physical data available for this mixturethan for other non-azeotropic mixtures. The experience andknowledge acquired in this project are possible to apply onother mixtures. Accurate calculations can be done for thesewhen more reliable data are available.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Publication and Content Type

rap (subject category)
vet (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view