Search: onr:"swepub:oai:research.chalmers.se:61e15b1b-f696-46fd-ad5b-5ff3e0cbeedd" >
A study on the rela...
A study on the relationship between energy performance and IEQ parameters in school buildings
-
- Cabovska, Blanka, 1990 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Teli, Despoina, 1980 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
- Dalenbäck, Jan-Olof, 1954 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
show more...
-
- Langer, Sarka, 1960 (author)
- Chalmers tekniska högskola,Chalmers University of Technology,IVL Svenska Miljöinstitutet AB,IVL Swedish Environmental Research Institute
-
- Ekberg, Lars, 1962 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
show less...
-
(creator_code:org_t)
- 2021-03-29
- 2021
- English.
-
In: E3S Web of Conferences. - : EDP Sciences. - 2555-0403 .- 2267-1242. ; 246
- Related links:
-
https://research.cha... (primary) (free)
-
show more...
-
https://www.e3s-conf...
-
https://research.cha...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Over the last decades, strong focus has been placed on the energy efficiency of buildings; not least school buildings. Energy performance (EP) of buildings is nowadays in principle described by one single indicator based on purchased energy in kWh/year.m2. Another important building performance aspect is the indoor environmental quality. This study's overarching goal is to identify school buildings with a good balance between energy performance and indoor environment. Thus, this paper investigates possible correlations between information given in energy performance certificates (EPCs/e.g. energy use, year of construction, type of ventilation) and measured indoor environmental parameters. The work comprises investigation of approximately 20 school buildings with different ventilation systems in Gothenburg. In-situ investigations of the buildings' properties and ventilation systems were conducted. Indoor environmental parameters were recorded during one week in each classroom. In this paper, indoor temperature, absolute humidity added indoors and CO2 concentration data are compared with the corresponding school's energy performance data and ventilation type. Results suggest that mechanically ventilated buildings have clearer relationships between energy performance, building indicators and measured indoor environment. For buildings such as naturally ventilated, the relationships are usually weak, and the values spread over much wider ranges.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Byggproduktion (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Construction Management (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering -- Building Technologies (hsv//eng)