SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:62420f4b-20f7-4751-a7ef-39693a3e33df"
 

Search: onr:"swepub:oai:research.chalmers.se:62420f4b-20f7-4751-a7ef-39693a3e33df" > Intermediate air fi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Intermediate air filters for general ventilation applications: An experimental evaluation of various filtration efficiency expressions

Shi, Bingbing, 1983 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Ekberg, Lars, 1962 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Langer, Sarka, 1960 (author)
IVL Svenska Miljöinstitutet AB,IVL Swedish Environmental Research Institute
 (creator_code:org_t)
Informa UK Limited, 2013
2013
English.
In: Aerosol Science and Technology. - : Informa UK Limited. - 0278-6826 .- 1521-7388. ; 47:5, s. 488-498
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Neither the European standard nor the US standard for classification of intermediate class filters comprises testing of filter performance with respect to ultrafine particles (UFPs) or particles of the most penetrating size (MPPS). This could turn out to be a major lack in classification standards since UFPs have been pointed out as a serious health hazard. In this study, fractional efficiencies of eight new full-scale bag filters and twenty-three new filter medium samples were determined. The influence of air velocity and aerosol type was investigated, and correlations between efficiencies for UFPs (EFUFPs), MPPS-sized particles (EFMPPS) and 0.4 μm-sized particles (EF0.4μm) were established. The tested bag filters were challenged by four aerosol types: a neutralized atomized oil aerosol, the same oil aerosol but non-neutralized, a non-neutralized thermally generated oil smoke, and a “natural” indoor aerosol. The tests were carried out at different air velocities through the filter medium, ranging between 0.08 m/s and 0.22 m/s. The relationships that were observed between EFUFPs, EFMPPS, and EF0.4μm appeared to be linear within the observed filtration efficiency ranges. These relationships were similar regardless of the test aerosol type used, but somewhat different for glass fiber filters than for charged synthetic filters. Generally, EFMPPS was 10–20% lower than EF0.4μm. The influence of air velocity variations on the size resolved efficiency was determined. The glass fiber filters showed practically the same fractional efficiencies regardless of whether the test aerosol was neutralized or not. However, the charged synthetic filters showed substantially lower efficiencies when tested with the non-neutralized aerosol compared to the case when the aerosol was neutralized.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Shi, Bingbing, 1 ...
Ekberg, Lars, 19 ...
Langer, Sarka, 1 ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Environmental En ...
Articles in the publication
Aerosol Science ...
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view