SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:7e86b582-09ad-4af4-8776-95208f1f203b"
 

Search: onr:"swepub:oai:research.chalmers.se:7e86b582-09ad-4af4-8776-95208f1f203b" > Millimeter-wave sen...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Millimeter-wave sensor based on a λ/2-line resonator for identification and dielectric characterization of non-ionic surfactants

Rodilla, Helena, 1982 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Kim, Anna, 1989 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Jeffries, Gavin, 1980 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Vukusic, Josip, 1972 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Jesorka, Aldo, 1967 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Stake, Jan, 1971 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show less...
 (creator_code:org_t)
2016-01-20
2016
English.
In: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 6
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Studies of biological and artificial membrane systems, such as niosomes, currently rely on the use of fluorescent tags, which can influence the system under investigation. For this reason, the development of label-free, non-invasive detection techniques is of great interest. We demonstrate an open volume label-free millimeter-wave sensing platform based on a coplanar waveguide, developed for identification and characterization of niosome constituents. A design based on a λ/2-line resonator was used and on-wafer measurements of transmission and reflection parameters were performed up to 110 GHz. Our sensor was able to clearly distinguish between common niosome constituents, non-ionic surfactants Tween 20 and Span 80, measuring a resonance shift of 3 GHz between them. The complex permittivities of the molecular compounds have been extracted. Our results indicate insignificant frequency dependence in the investigated frequency range (3 GHz – 110 GHz). Values of permittivity around 3.0 + 0.7i and 2.2 + 0.4i were obtained for Tween 20 and Span 80, respectively.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Annan kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Other Chemical Engineering (hsv//eng)
NATURVETENSKAP  -- Kemi -- Annan kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Other Chemistry Topics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view