SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:a4be3a94-773e-411a-9401-fdfe2740a88a"
 

Search: onr:"swepub:oai:research.chalmers.se:a4be3a94-773e-411a-9401-fdfe2740a88a" > Calculation of Ener...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Calculation of Energy-Deposition Distributions and Microdosimetric Estimation of the Biological Effect of a 9C Beam

Mancusi, Davide, 1980 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Sihver, Lembit, 1962 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Niita, K. (author)
show more...
Li, Q (author)
Sato, T. (author)
Iwase, H. (author)
Iwamoto, Y. (author)
Matsuda, N. (author)
Sakamoto, Y. (author)
Nakashima, H. (author)
show less...
 (creator_code:org_t)
2009
2009
English.
In: Radiation and Environmental Biophysics. - 1432-2099 .- 0301-634X. ; 48:2, s. 135-143
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Among the alternative beams being recently considered for external cancer radiotherapy, C-9 has received some attention because it is expected that its biological effectiveness could be boosted by the beta-delayed emission of two alpha particles and a proton that takes place at the ion-stopping site. Experiments have been performed to characterise this exotic beam physically and models have been developed to estimate quantitatively its biological effect. Here, the particle and heavy-ion transport code system (PHITS ) is used to calculate energy-deposition and linear energy transfer distributions for a C-9 beam in water and the results are compared with published data. Although PHITS fails to reproduce some of the features of the distributions, it suggests that the decay of C-9 contributes negligibly to the energy-deposition distributions, thus contradicting the previous interpretation of the measured data. We have also performed a microdosimetric calculation to estimate the biological effect of the decay, which was found to be negligible; previous microdosimetric Monte-Carlo calculations were found to be incorrect. An analytical argument, of geometrical nature, confirms this conclusion and gives a theoretical upper bound on the additional biological effectiveness of the decay. However, no explanation can be offered at present for the observed difference in the biological effectiveness between C-9 and C-12; the reproducibility of this surprising result will be verified in coming experiments.

Subject headings

NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view