Microdosimetry for a carbon ion beam using track-etched detectors

Ambrozova, I. (author)
Czech Academy of Sciences
Vondracek, V. (author)
Šefl, M. (author)
Ceske Vysoke Uceni Technicke v Praze,Czech Technical University in Prague
show more...
Stepan, V. (author)
Centre d'Etudes Nucleaires de Bordeaux Gradignan,Czech Academy of Sciences
Pachnerova Brabcová, Katerina, 1978 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Ploc, Ondrej, 1979 (author)
Czech Academy of Sciences
Incerti, S. (author)
Centre d'Etudes Nucleaires de Bordeaux Gradignan
Davidkova, M. (author)
Czech Academy of Sciences
show less...
 (creator_code:org_t)
2015-04-09
2015
English.
In: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 166:1-4, s. 247-252
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth-dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u-1 in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8-10 keV μm-1, while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams.

Subject headings

NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view