SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:c28a8d9f-1af3-440a-963b-24b6be2f12b6"
 

Search: onr:"swepub:oai:research.chalmers.se:c28a8d9f-1af3-440a-963b-24b6be2f12b6" > Time optimization o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003292naa a2200397 4500
001oai:research.chalmers.se:c28a8d9f-1af3-440a-963b-24b6be2f12b6
003SwePub
008171007s2016 | |||||||||||000 ||eng|
024a https://doi.org/10.1016/j.apradiso.2016.01.0112 DOI
024a https://research.chalmers.se/publication/2350492 URI
040 a (SwePub)cth
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Holmgren, S.u Totalförsvarets forskningsinstitut (FOI),Swedish Defence Research Agency (FOI)4 aut
2451 0a Time optimization of Sr-90 measurements: Sequential measurement of multiple samples during ingrowth of Y-90
264 1b Elsevier BV,c 2016
520 a The aim of this paper is to contribute to a more rapid determination of a series of samples containing Sr-90 by making the Cherenkov measurement of the daughter nuclide Y-90 more time efficient. There are many instances when an optimization of the measurement method might be favorable, such as; situations requiring rapid results in order to make urgent decisions or, on the other hand, to maximize the throughput of samples in a limited available time span. In order to minimize the total analysis time, a mathematical model was developed which calculates the time of ingrowth as well as individual measurement times for n samples in a series. This work is focused on the measurement of Y-90 during ingrowth, after an initial chemical separation of strontium, in which it is assumed that no other radioactive strontium isotopes are present. By using a fixed minimum detectable activity (MDA) and iterating the measurement time for each consecutive sample the total analysis time will be less, compared to using the same measurement time for all samples. It was found that by optimization, the total analysis time for 10 samples can be decreased greatly, from 21 h to 6.5 h, when assuming a MDA of 1 Bq/L and at a background count rate of approximately 0.8 cpm.
650 7a NATURVETENSKAPx Kemix Oorganisk kemi0 (SwePub)104042 hsv//swe
650 7a NATURAL SCIENCESx Chemical Sciencesx Inorganic Chemistry0 (SwePub)104042 hsv//eng
650 7a NATURVETENSKAPx Fysikx Subatomär fysik0 (SwePub)103012 hsv//swe
650 7a NATURAL SCIENCESx Physical Sciencesx Subatomic Physics0 (SwePub)103012 hsv//eng
653 a Y-90
653 a Sequential measurement
653 a Sr-90
653 a Multiple samples
653 a Optimization
700a Tovedal, A.u Totalförsvarets forskningsinstitut (FOI),Swedish Defence Research Agency (FOI)4 aut
700a Björnham, Oscaru Totalförsvarets forskningsinstitut (FOI),Swedish Defence Research Agency (FOI)4 aut
700a Ramebäck, Henrik,d 1967u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)rameback
710a Totalförsvarets forskningsinstitut (FOI)b Chalmers tekniska högskola4 org
773t Applied Radiation and Isotopesd : Elsevier BVg 110, s. 150-154q 110<150-154x 0969-8043x 1872-9800
856u http://dx.doi.org/10.1016/j.apradiso.2016.01.011y FULLTEXT
8564 8u https://doi.org/10.1016/j.apradiso.2016.01.011
8564 8u https://research.chalmers.se/publication/235049

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view