SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:cbe04adc-0ef7-44c3-9fa1-a0210d9cc12a"
 

Search: onr:"swepub:oai:research.chalmers.se:cbe04adc-0ef7-44c3-9fa1-a0210d9cc12a" > Design and manufact...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • de Lazzari, Mattia,1996Chalmers tekniska högskola,Chalmers University of Technology (author)

Design and manufacture procedures of phantoms for hyperthermia QA guidelines

  • Article/chapterEnglish2023

Publisher, publication year, extent ...

  • 2023

Numbers

  • LIBRIS-ID:oai:research.chalmers.se:cbe04adc-0ef7-44c3-9fa1-a0210d9cc12a
  • https://doi.org/10.23919/EuCAP57121.2023.10133264DOI
  • https://research.chalmers.se/publication/536321URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:kon swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • Clinical outcome of hyperthermia therapy (HT) is strongly correlated with the thermal dose delivered into the tumor. Achieving of prescribed temperature distribution within the target area should therefore the primary objective of any HT treatment. The Quality Assurance (QA) guidelines developed in past decennium by ESHO-TC establish the physical characterization and prescribe the safeguards to ensure that the clinically used equipment is capable of achieving adequate temperatures. The direct implementation of these guidelines is however limited by the lack of suitable phantom materials. To address this issue, we propose (i) a novel material to mimic fat tissue and (ii) a standardized phantom verification of phased array applicators for deep HT in Head and Neck (H&N) and extremities. In particular, (i) a fat-phantom composed of an ethylcellulose based oleogel exhibit equivalent dielectric and thermal properties with the required mechanical stability even at elevated temperatures, while (ii) the standardized phantom provides the means to capture the thermal profiles to evaluate the performance indicators in reproducible manner. Both phantoms thus bears a great potential for their extensive use in QA procedures.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Napieralski, WojtekChalmers tekniska högskola,Chalmers University of Technology (author)
  • Nguyen, ThienChalmers tekniska högskola,Chalmers University of Technology (author)
  • Ström, Anna,1976Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)annastr (author)
  • Dobsicek Trefna, Hana,1979Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)hanatre (author)
  • Chalmers tekniska högskola (creator_code:org_t)

Related titles

  • In:17th European Conference on Antennas and Propagation, EuCAP 2023

Internet link

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
de Lazzari, Matt ...
Napieralski, Woj ...
Nguyen, Thien
Ström, Anna, 197 ...
Dobsicek Trefna, ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Equipmen ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view