SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:d1748b55-9647-4f85-8570-0e88f0b07d70"
 

Search: onr:"swepub:oai:research.chalmers.se:d1748b55-9647-4f85-8570-0e88f0b07d70" > Circulating Current...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Circulating Current Suppression Strategies for D-STATCOM Based on Modular Multilevel Converters

Pereira, H. A. (author)
Universidade Federal de Minas Gerais,Universidade Federal de Vicosa,Federal University of Viçosa
Haddioui, M. R. (author)
Aalborg Universitet,Aalborg University
de Oliveira, L. O. M. (author)
Universidade Federal de Vicosa,Federal University of Viçosa
show more...
Mathe, L. (author)
Aalborg Universitet,Aalborg University
Bongiorno, Massimo, 1976 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Teodorescu, Remus, 1965 (author)
Aalborg Universitet,Aalborg University
show less...
 (creator_code:org_t)
ISBN 9781479987795
2015
2015
English.
In: 2015 Ieee 13th Brazilian Power Electronics Conference and 1st Southern Power Electronics Conference (Cobep/Spec). - 9781479987795 ; , s. 1-6
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • This work focuses on the circulating current measurement of a STAtic synchronous COMpensator (STATCOM) based on Modular Multilevel Converter (MMC). In a Delta (D) connected MMC-based STATCOM configuration the currents are divided in two parts: grid currents and circulating currents. The latest circulates between legs and has no direct impact on the output current, but it has a third harmonic component, which causes problems in the circulating current control. Thus, this work evaluates three circulating current measurement strategies, with focus on the converter characteristics improvement, such as losses reduction. A classical strategy is compared with other two strategies using a Second Order Generalized Integrator (SOGI) structure. The first proposed strategy eliminates the third harmonic from the circulating current and the second detects the fundamental component of the circulating current eliminating the other harmonic components. Simulated and experimental results show that this strategies achieve reduction in the circulating current, and consequently reduction in the STATCOM losses.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Keyword

STAtic synchronous COMpensator (STATCOM)
Voltage-Source Converters (VSCs)
performance
Circulating current
pwm statcom
design
Engineering
Modular Multilevel Converters (MMCs)
cascade converter
Energy & Fuels

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view