Search: onr:"swepub:oai:slubar.slu.se:98064" >
TIMFIE Sampler-A Ne...
TIMFIE Sampler-A New Time-Integrating, Active, Low-Tech Sampling Device for Quantitative Monitoring of Pesticides in Whole Water
-
- Jonsson, Ove (author)
- Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för vatten och miljö,Department of Aquatic Sciences and Assessment
-
- Paulsson, Elin (author)
- Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för vatten och miljö,Department of Aquatic Sciences and Assessment
-
- Kreuger, Jenny (author)
- Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för vatten och miljö,Department of Aquatic Sciences and Assessment
-
(creator_code:org_t)
-
- 2018-12-08
- 2019
- English.
-
In: Environmental Science and Technology. - : American Chemical Society (ACS). - 0013-936X .- 1520-5851. ; 53, s. 279-286
- Related links:
-
https://pubs.acs.org...
-
show more...
-
https://res.slu.se/i...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- The need for inexpensive, time-averaged, quantitative determination of pesticides and other organic pollutants in whole water is not matched by the field sampling procedures available. Our new Time-Integrating, MicroFlow, In-line Extraction (TIMFIE) sampler comprises a low-tech syringe pump driven by a rubber band and connected to a flow restrictor enabling low microliter per minute water flow through a solid phase extraction (SPE) cartridge. This allows target compounds to be continuously extracted in the field over 1 week. The extracted water ends up in the syringe, where sample volume is accurately determined. TIMFIE followed by online SPE-LC-MS/MS determination was validated for 72 selected pesticides, and, except for three compounds, detection limit was 0.1-1 ng/L. In a field study, concentrations in TIMFIE samples and in grab samples were compared. Following TIMFIE sampling, on average 19 pesticides per sample were quantified, compared with nine pesticides per sample with grab sampling, as a result of the extra in-field concentration step. Duplicate TIMFIE sampling showed Pearson's correlation coefficient r = 0.998. Comparing concentrations from TIMFIE sampling to grab sampling resulted in ratios between 0.05 and 16.5 (mean 1.7; r = 0.532), demonstrating a discrepancy between the two sampling strategies and possible underestimation of chronic exposure by grab sampling.
Subject headings
- LANTBRUKSVETENSKAPER -- Annan lantbruksvetenskap -- Miljö- och naturvårdsvetenskap (hsv//swe)
- AGRICULTURAL SCIENCES -- Other Agricultural Sciences -- Environmental Sciences related to Agriculture and Land-use (hsv//eng)
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database