SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:hj-63326"
 

Sökning: onr:"swepub:oai:DiVA.org:hj-63326" > Image quality and m...

  • Rosendahl, LeneLinköpings universitet,Klinisk fysiologi,Hälsouniversitetet (författare)

Image quality and myocardial scar size determined with magnetic resonance imaging in patients with permanent atrial fibrillation : A comparison of two imaging protocols

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • John Wiley & Sons,2010
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:hj-63326
  • https://urn.kb.se/resolve?urn=urn:nbn:se:hj:diva-63326URI
  • https://doi.org/10.1111/j.1475-097X.2009.00914.xDOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-72074URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-54159URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding Agency:Linköping Heart Centre
  • Background: Magnetic resonance imaging (MRI) of the heart generally requires breath holding and a regular rhythm. Single shot 2D steady-state free precession (SS_SSFP) is a fast sequence insensitive to arrhythmia as well as breath holding. Our purpose was to determine image quality, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and infarct size with a fast single shot and a standard segmented MRI sequence in patients with permanent atrial fibrillation and chronic myocardial infarction.Methods: Twenty patients with chronic myocardial infarction and ongoing atrial fibrillation were examined with inversion recovery SS_SSFP and segmented inversion recovery 2D fast gradient echo (IR_FGRE). Image quality was assessed in four categories: delineation of infarcted and non-infarcted myocardium, occurrence of artefacts and overall image quality. SNR and CNR were calculated. Myocardial volume (ml) and infarct size, expressed as volume (ml) and extent (%), were calculated, and the methodological error was assessed.Results: SS_SSFP had significantly better quality scores in all categories (P = 0·037, P = 0·014, P = 0·021, P = 0·03). SNRinfarct and SNRblood were significantly better for IR_FGRE than for SS_SSFP (P = 0·048, P = 0·018). No significant difference was found in SNRmyocardium and CNR. The myocardial volume was significantly larger with SS_SSFP (170·7 versus 159·2 ml, P<0·001), but no significant difference was found in infarct volume and infarct extent.Conclusion: SS_SSFP displayed significantly better image quality than IR_FGRE. The infarct size and the error in its determination were equal for both sequences, and the examination time was shorter with SS_SSFP.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ahlander, Britt-Marie,1954-Department of Radiology, Ryhov County Hospital, Jönköping, Sweden(Swepub:oru)bear (författare)
  • Björklund, Per-GunnarDepartment of Clinical Physiology, Ryhov County Hospital, Jönköping, Sweden (författare)
  • Blomstrand, PeterDepartment of Clinical Physiology, Ryhov County Hospital, Jönköping, Sweden(Swepub:hj)BLOPET (författare)
  • Brudin, LarsLinköpings universitet,Klinisk fysiologi,Hälsouniversitetet(Swepub:liu)larbr27 (författare)
  • Engvall, JanÖstergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken(Swepub:liu)janen74 (författare)
  • Linköpings universitetKlinisk fysiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Physiology and Functional Imaging: John Wiley & Sons30:2, s. 122-1291475-09611475-097X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy