SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-11640"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-11640" > Energy filtering wi...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004005naa a2200625 4500
001oai:DiVA.org:kth-11640
003SwePub
008091127s2010 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-116402 URI
024a https://doi.org/10.1093/rpd/ncq0492 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Fredenberg, Erik,c PhD,d 1979-u KTH,Medicinsk bildfysik4 aut0 (Swepub:kth)u17g0bk4
2451 0a Energy filtering with x-ray lenses: Optimization for photon-counting mammography
264 c 2010-02-23
264 1b Oxford University Press (OUP),c 2010
338 a electronic2 rdacarrier
500 a QC 20100714. Uppdaterad från submitted till published (20100714)
520 a Chromatic properties of the multi-prism and prism-array x-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The line-shaped foci of the lenses are optimal for coupling to photon-counting silicon strip detectors in a scanning system. A theoretical model was developed and used to investigate the benefit of two lenses compared to an absorption-filtered reference system. The dose reduction of the MPL filter was 15% compared to the reference system at matching scan time, and the spatial resolution was higher. The dose of the PAL-filtered system was found to be 20% lower than for the reference system at equal scan time and resolution, and only 20% higher than for a monochromatic beam. An investigation of some practical issues remains, including the feasibility of brilliant-enough x-ray sources and manufacturing of a polymer PAL.
650 7a TEKNIK OCH TEKNOLOGIERx Annan teknikx Övrig annan teknik0 (SwePub)211992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Other Engineering and Technologiesx Other Engineering and Technologies not elsewhere specified0 (SwePub)211992 hsv//eng
650 7a NATURVETENSKAPx Fysikx Atom- och molekylfysik och optik0 (SwePub)103022 hsv//swe
650 7a NATURAL SCIENCESx Physical Sciencesx Atom and Molecular Physics and Optics0 (SwePub)103022 hsv//eng
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng
653 a x-ray imaging
653 a mammography
653 a x-ray optics
653 a multiprism lens
653 a prism-array lens
653 a energy filtering
653 a radiation dose
653 a spatial resolution
653 a exposure time
653 a Other engineering physics
653 a Övrig teknisk fysik
653 a Optical physics
653 a Optisk fysik
653 a Radiological research
653 a Radiologisk forskning
653 a Medical engineering
653 a Medicinsk teknik
700a Cederström, Björnu KTH,Medicinsk bildfysik,Medical Imaging4 aut0 (Swepub:kth)u1oerth9
700a Danielsson, Matsu KTH,Medicinsk bildfysik,Medical Imaging4 aut0 (Swepub:kth)u1m3qe0f
710a KTHb Medicinsk bildfysik4 org
773t Radiation Protection Dosimetryd : Oxford University Press (OUP)g 139, s. 339-342q 139<339-342x 0144-8420x 1742-3406
856u https://kth.diva-portal.org/smash/get/diva2:278580/FULLTEXT01.pdfx primaryx Raw objecty fulltext:postprint
856u http://kth.diva-portal.org/smash/get/diva2:278580/FULLTEXT01
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-11640
8564 8u https://doi.org/10.1093/rpd/ncq049

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy