SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-266924"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-266924" > Robustness of optim...

Robustness of optimal energy thresholds in photon-counting spectral CT

Zheng, Yifan (författare)
KTH,Fysik
Yveborg, Moa (författare)
Prismat Sensors AB, Roslagstullsbacken 21, S-10691 Stockholm, Sweden.
Grönberg, Fredrik (författare)
KTH,Medicinsk bildfysik
visa fler...
Xu, Cheng (författare)
KTH,Medicinsk bildfysik
Su, Qianqian (författare)
Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China.;Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China.
Danielsson, Mats, Professor (författare)
KTH,Medicinsk bildfysik
Persson, Mats, 1987- (författare)
KTH,Medicinsk bildfysik
visa färre...
 (creator_code:org_t)
ELSEVIER, 2020
2020
Engelska.
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : ELSEVIER. - 0168-9002 .- 1872-9576. ; 953
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An important question when developing photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing signal-difference-to-noise ratio squared (SDNR2) in an optimally weighted image and signal-to-noise ratio squared (SNR2) in a gadolinium basis image in a silicon-strip detector and a cadmium zinc telluride (CZT) detector, factoring in pileup and imperfect energy response based on real-world detector systems. To investigate to what extent one single set of thresholds could be applied in various imaging tasks, the robustness of optimal thresholds with 2 to 8 bins is examined with the variation of phantom thicknesses, target materials and detector configurations. In contrast to previous studies, the optimal threshold locations do not always increase with increasing attenuation if pileup is included. With respect to the tradeoff between higher SDNR2 or SNR2 and less data, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 and setting optimal thresholds for a 50 cm phantom yields robust SNR2 with 6 to 8 bins in the silicon-strip detector. Furthermore, setting optimal thresholds for a 30 cm phantom yields robust SDNR2 or SNR2 with 6 to 8 bins and a pixel size less than or equal to 0.5 x 0.5 mm(2) in the CZT detector.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Photon counting
Spectral CT
Threshold optimization
Silicon-strip detector
CZT detector

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy