Electrohydraulic Vascular Compression Device (e-VaC) with Integrated Sensing and Controls

  • Artikel/kapitelEngelska2023

Förlag, utgivningsår, omfång ...

  • 2022-11-13
  • Wiley,2023
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-329003
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-329003URI
  • https://doi.org/10.1002/admt.202201196DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20230614
  • Right ventricular (RV) failure remains a significant clinical burden particularly during the perioperative period surrounding major cardiac surgeries, such as implantation of left ventricular assist devices (LVADs), bypass procedures or valvular surgeries. Device solutions designed to support the function of the RV do not keep up with the pace of development of left-sided solutions, leaving the RV vulnerable to acute failure in the challenging hemodynamic environments of the perioperative setting. This work describes the design of a biomimetic, soft, conformable sleeve that can be prophylactically implanted on the pulmonary artery to support RV ventricular function during major cardiac surgeries, through afterload reduction and augmentation of flow. Leveraging electrohydraulic principles, a technology is proposed that is non-blood contacting and obviates the necessity for drivelines by virtue of being electrically powered. In addition, the integration of an adjacent is demonstrate, continuous pressure sensing module to support physiologically adaptive control schemes based on a real-time biological signal. In vitro experiments conducted in a pulsatile flow-loop replicating physiological flow and pressure conditions show a reduction of mean pulmonary arterial pressure of 8 mmHg (25% reduction), a reduction in peak systolic arterial pressure of up to 10 mmHg (20% reduction), and a concomitant 19% increase in diastolic pulmonary flow. Computational simulations further predict substantial augmentation of cardiac output as a result of reduced RV ventricular stress and RV dilatation. 

Ämnesord och genrebeteckningar

  • TEKNIK OCH TEKNOLOGIER Medicinteknik hsv//swe
  • ENGINEERING AND TECHNOLOGY Medical Engineering hsv//eng
  • continuous sensing
  • electrohydraulic actuator
  • mechanical cardiac support
  • right ventricular failure
  • Artificial heart
  • Biomimetics
  • Cardiovascular surgery
  • Failure (mechanical)
  • Heart
  • Hydraulic actuators
  • Left ventricular assist devices
  • Mechanical actuators
  • % reductions
  • Cardiac-surgery
  • Compression devices
  • Electro-hydraulic actuator
  • Electro-hydraulics
  • Mechanical
  • Right ventricular
  • Hydraulics

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Kight, A. (författare)
  • Liang, X. (författare)
  • Han, A. K. (författare)
  • Ennis, D. B. (författare)
  • Hiesinger, W. (författare)
  • Dual, Seraina A.KTH,Medicinteknik och hälsosystem(Swepub:kth)u1zh79lk (författare)
  • Cutkosky, M. R. (författare)
  • KTHMedicinteknik och hälsosystem (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Advanced Materials Technologies: Wiley8:4, s. 2201196-2365-709X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy