Renal artery stenosis : extracting quantitative parameters with a mathematical model fitted to magnetic resonance blood flow data
-
- Larsson, Martin (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet
-
- Persson, Anders (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
-
- Eriksson, Per (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Institutionen för medicin och hälsa,Hälsouniversitetet,Njurmedicinska kliniken
-
visa fler...
-
- Kihlberg, Johan (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet
-
- Smedby, Örjan (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping
-
visa färre...
-
(creator_code:org_t)
- 2007
- 2008
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 27:1, s. 140-147
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://onlinelibrar...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: To investigate the feasibility of quantitative parameter extraction from a mathematical model fitted to renal artery magnetic resonance flow data.Material and methods: Sixteen subjects, 8 patients and 8 normal controls, were examined with cine phase-contrast velocity measurements, and blood flow data from the aorta and both renal arteries were extracted by means of contour detection. A mathematical model with eight parameters describing the time, duration and amplitude of the systolic acceleration and the diastolic deceleration was fitted to the aorta and renal artery blood flow data from each subject. The curve fitting was evaluated with R2 values. Statistical analysis was performed with unpaired Wilcoxon tests and stepwise logistic regression.Results: Three data sets out of 48 yielded R2 values below 0.80 and were considered unreliable for parameter estimation. Basal flow was significantly, and systolic peak amplitude almost significantly, lower in stenotic arteries. Logistic regression indicated that two parameters describing basal flow and the duration of acceleration can accurately predict stenosis.Conclusion: The results suggest that it is technically feasible to fit a mathematical model to renal blood flow data, extracting quantitative parameters that may prove useful for quantification and diagnosis of renal artery stenosis.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Nyckelord
- Flow measurement
- Magnetic Resonance Angiography
- Blood flow
- Renal artery stenosis
- MEDICINE
- MEDICIN