SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-27057"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-27057" > Bioanalysis of race...

Bioanalysis of racemic reboxetine and its desethylated metabolite in a therapeutic drug monitoring setting using solid phase extraction and HPLC

Öhman, Daniel, 1973- (författare)
Linköpings universitet,Klinisk farmakologi,Hälsouniversitetet
Norlander, Björn, 1942- (författare)
Linköpings universitet,Klinisk farmakologi,Hälsouniversitetet
Peterson, Curt, 1944- (författare)
Linköpings universitet,Klinisk farmakologi,Hälsouniversitetet
visa fler...
Bengtsson, Finn, 1956- (författare)
Linköpings universitet,Psykiatri,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Ovid Technologies (Wolters Kluwer Health), 2001
2001
Engelska.
Ingår i: Therapeutic Drug Monitoring. - : Ovid Technologies (Wolters Kluwer Health). - 0163-4356 .- 1536-3694. ; 23:1, s. 27-34
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reboxetine isa new antidepressant drug acting as a potent and selective noradrenaline reuptake inhibitor on the noradrenergic neuronal system. Because of an expected interindividual variability in drug metabolism in the clinical practice the need for therapeutic drug monitoring routines in psychiatry is always a prominent feature. In this application, the preferred bioanalytic methodology was solid phase extraction combined with reversed-Phase high-Performance liquid chromatography and ultraviolet detection at 210 nm. The technique proved reliable, with interday and intraday variation of less than 5% and a quantification limit for reboxetine and one of its main metabolites O-Desethylreboxetine (O-Reboxetine) at 5 and 30 nmol/L, respectively. The method was applied on serum samples from 38 patients treated chronically with reboxetine. These samples were drawn as trough levels in steady state with a dosage range of 2-16 mg/day. They evidenced a mean reboxetine concentration that was fairly linear and dose proportional, although the variance in concentration was large between patients, even those taking the same dosage. O-Reboxetine was detected in quantifiable amounts in only 1 of the 38 patients (<3%). In conclusion, these results suggest that a routine reboxetine therapeutic drug monitoring service that is robust enough to produce reliable and reproducible results may be introduced into everyday clinical practice.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy