Sökning: onr:"swepub:oai:DiVA.org:liu-45734" > Reversible hydropho...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03305naa a2200373 4500 | |
001 | oai:DiVA.org:liu-45734 | |
003 | SwePub | |
008 | 091011s2004 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-457342 URI |
024 | 7 | a https://doi.org/10.1007/s00604-003-0174-22 DOI |
040 | a (SwePub)liu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Zhou, Yeu Linköpings universitet,Tekniska högskolan,Sensorvetenskap och Molekylfysik4 aut0 (Swepub:liu)yezh23 |
245 | 1 0 | a Reversible hydrophobic barriers introduced by microcontact printing :b Application to protein microarrays |
264 | 1 | b Springer Science and Business Media LLC,c 2004 |
338 | a print2 rdacarrier | |
520 | a Microcontact printing (µCP) has been used to introduce temporary hydrophobic barriers on carboxymethylated dextran (CMD) hydrogels on gold. Among the investigated types of inks, tetraoctadecylammonium bromide (TOAB), electrostatically bound to the CMD layer, provided the most well-defined features both with respect to pattern-definition and reversibility upon exposure to a regeneration solution. The printed patterns were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), microscopic wetting and imaging null ellipsometry to explore the influence of concentration of ink solution and contact time on the appearance of the printed layer. AFM revealed that the printed TOAB molecules aggregated into clusters rather than into a homogeneous mono- or multilayer on the CMD hydrogel. It was also observed that printed areas of TOAB that are larger than 25?µm are inhomogeneous most likely because of an edge transfer lithography (ETL) mechanism. A protein model system based on Protein A-rabbit antimouse Fc ? was used to evaluate the potential of the patterned surface as a protein microarray chip by means of surface plasmon microscopy (SPM). Moreover, non-specific adsorption of several proteins onto TOAB barriers was also studied using surface plasmon resonance (SPR), and it is evident that undesired adsorption can be eliminated by removing barriers after ligand immobilization, but prior to analyte exposure, by treating the patterned surface with a simple salt regeneration solution. © Springer-Verlag/Wien 2004. | |
653 | a Carboxymethylated dextran | |
653 | a Microcontact printing | |
653 | a Protein microarrays | |
653 | a Reversible hydrophobic barrier | |
653 | a Surface plasmon microscopy | |
653 | a TECHNOLOGY | |
653 | a TEKNIKVETENSKAP | |
700 | 1 | a Andersson, Olofu Linköpings universitet,Tekniska högskolan,Sensorvetenskap och Molekylfysik4 aut0 (Swepub:liu)oloan51 |
700 | 1 | a Lindberg, P.u Biacore AB, Rapsgatan 7, S-754 50 Uppsala, Sweden4 aut |
700 | 1 | a Liedberg, Bou Linköpings universitet,Tekniska högskolan,Sensorvetenskap och Molekylfysik4 aut0 (Swepub:liu)boli31 |
710 | 2 | a Linköpings universitetb Tekniska högskolan4 org |
773 | 0 | t Microchimica Actad : Springer Science and Business Media LLCg 146:3-4, s. 193-205q 146:3-4<193-205x 0026-3672x 1436-5073 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-45734 |
856 | 4 8 | u https://doi.org/10.1007/s00604-003-0174-2 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy