Motion compensated digital subtraction angiography
-
- Hemmendorff, M. (författare)
- Linköpings universitet,Institutionen för systemteknik,Tekniska högskolan,SECTRA, Teknikringen 2, SE-583 30 Linköping, Sweden
-
- Knutsson, Hans (författare)
- Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Bildbehandling
-
- Andersson, Mats (författare)
- Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Bildbehandling
-
visa fler...
-
- Kronander, T. (författare)
- SECTRA, Teknikringen 2, SE-583 30 Linköping, Sweden
-
visa färre...
-
(creator_code:org_t)
- 1999
- 1999
- Engelska.
-
Ingår i: Proceedings of SPIE's International Symposium on Medical Imaging, vol 3661, 1999.
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://liu.diva-por... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Digital subtraction angiography, whether based on traditional X-ray or MR, suers from patient motion artifacts. Until now, the usual remedy is to pixel shift by hand, or in some cases performing a global pixel shift semi-automatically. This is time consuming, and cannot handle rotations or local varying deformations over the image. We have developed a fully automatic algorithm that provides for motion compensation in the presence of large local deformations. Our motion compensation is very accurate for ordinary motions, including large rotations and deformations. It does not matter if the motions are irregular over time. For most images, it takes about a second per image to get adequate accuracy. The method is based on using the phase from lter banks of quadrature lters tuned in dierent directions and frequencies. Unlike traditional methods for optical ow and correlation, our method is more accurate and less susceptible to disturbing changes in the image, e.g. a moving contrast bolus. The implications for common practice are that radiologists' time can be significantly reduced in ordinary peripheral angiographies and that the number of retakes due to large or local motion artifacts will be much reduced.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Nyckelord
- Motion Compensation
- Motion Estimation
- Digital Subtraction Angiography
- Aperture Problem
- Pixelshift
- Automatic
- Quadrature Filter
- Regularization
- Medical engineering
- Medicinsk teknik
- TECHNOLOGY
Publikations- och innehållstyp
- ref (ämneskategori)
- kon (ämneskategori)