Peripheral resolution and contrast sensitivity : Effects of stimulus drift
-
- Venkataraman, Abinaya Priya (författare)
- KTH Royal Institute of Technology
-
- Lewis, Peter (författare)
- Linnéuniversitetet,Institutionen för medicin och optometri (MEO)
-
- Unsbo, Peter (författare)
- KTH,Biomedicinsk fysik och röntgenfysik,KTH Royal Institute of Technology
-
visa fler...
-
- Lundström, Linda (författare)
- KTH,Biomedicinsk fysik och röntgenfysik,KTH Royal Institute of Technology
-
visa färre...
-
(creator_code:org_t)
- Pergamon Press, 2017
- 2017
- Engelska.
-
Ingår i: Vision Research. - : Pergamon Press. - 0042-6989 .- 1878-5646. ; 133, s. 145-149
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://doi.org/10.1...
-
http://www.sciencedi...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Optimal temporal modulation of the stimulus can improve foveal contrast sensitivity. This studyevaluates the characteristics oftheperipheral spatiotemporal contrast sensitivity function in normal-sighted subjects.The purpose is to identify a temporal modulation that can potentially improve the remaining peripheral visual function in subjects with central visual field loss. High contrast resolution cut-off for grating stimuli with four temporal frequencies (0, 5, 10 and 15 Hz drift) was first evaluated in the 10° nasal visual field.Resolution contrast sensitivity for all temporal frequencies was then measured at four spatial frequencies between 0.5 cycles per degree (cpd) and the measured stationary cut-off. All measurements were performed with eccentric optical correction. Similar to foveal vision, peripheral contrast sensitivity is highest for a combination of low spatial frequency and 5 to 10 Hz drift. At higher spatial frequencies, there was a decrease in contrast sensitivity with 15 Hz drift.Despitethis decrease, the resolution cut-off did not vary largely between the different temporal frequencies tested. Additional measurements of contrast sensitivity at 0.5 cpd and resolution cut-off for stationary (0 Hz) and 7.5 Hz stimuli performed at 10, 15, 20 and 25° in the nasal visual field also showed the same characteristics across eccentricities.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)
- NATURVETENSKAP -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
Nyckelord
- Contrast sensitivity
- Drifting gratings
- Peripheral vision
- Spatial frequency
- Temporal frequency
- Optometry
- Optometri
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)