SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:mau-15736"
 

Sökning: onr:"swepub:oai:DiVA.org:mau-15736" > Drilling dimension ...

Drilling dimension effects in early stages of osseointegration and implant stability in a canine model

Baires-Campos, Felipe-Eduardo (författare)
Jimbo, Ryo (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Bonfante, Estevam-Augusto (författare)
visa fler...
Fonseca-Oliveira, Maiolino-Thomaz (författare)
Moura, Camila (författare)
Zanetta-Barbosa, Darceny (författare)
Coelho, Paulo-Guilherme (författare)
visa färre...
 (creator_code:org_t)
Medicina Oral S L, 2015
2015
Engelska.
Ingår i: Medicina Oral. - : Medicina Oral S L. - 1698-4447 .- 1698-6946. ; 20:4, s. E471-E479
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4 1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent. Results: The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32). Conclusions: Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Histomorphometry
biomechanical
in vivo
initial stability
insertion torque
osseointegration

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy