Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST

  • Artikel/kapitelEngelska2012

Förlag, utgivningsår, omfång ...

  • Clare, Ireland :Elsevier,2012
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:oru-27174
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-27174URI
  • https://doi.org/10.1016/j.ejrad.2011.06.034DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding agency:Research Committee of Örebro County Council 
  • Objective: To investigate the accuracy of velocity measurements in patients with aortic valve stenosis using phase contrast (PC) imaging accelerated with SENSE (Sensitivity Encoding) and k-t BLAST (Broad-use Linear Acquisition Speed-up Technique).Methods: Accelerated quantitative breath hold PC measurements, using SENSE and k-t BLAST, were performed in twelve patients whose aortic valve stenosis had been initially diagnosed using echocardiography. Stroke volume (SV) and peak velocity measurements were performed on each subject in three adjacent slices using both accelerating methods.Results: The peak velocities measured with PC MRI using SENSE were -8.0±9.5% lower (p<0.01) compared to the peak velocities measured with k-t BLAST and the correlation was r=0.83. The stroke volumes when using SENSE were slightly higher 0.4±17.1 ml compared to the SV obtained using k-t BLAST but the difference was not significant (p>0.05).Conclusions In this study higher peak velocities were measured in patients with aortic stenosis when combining k-t BLAST with PC MRI compared to PC MRI using SENSE. A probable explanation of this difference is the higher temporal resolution achieved in the k-t BLAST measurement. There was, however, no significant difference between calculated SV based on PC MRI using SENSE and k-t BLAST, respectively.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Emilsson, Kent,1963-Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)kten (författare)
  • Rask, PeterDepartment of Clinical Physiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)prk (författare)
  • Kähäri, AndersDepartment of Radiology, Örebro University Hospital, Örebro, Sweden (författare)
  • Department of Medical Physics, Örebro University Hospital, Örebro, SwedenDepartment of Clinical Physiology, Örebro University Hospital, Örebro, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Journal of RadiologyClare, Ireland : Elsevier81:9, s. 2203-22070720-048X1872-7727

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Thunberg, Per, 1 ...
Emilsson, Kent, ...
Rask, Peter
Kähäri, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy