SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-49633"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-49633" > Temperature measure...

  • Geijer, Håkan,1961-Örebro universitet,Institutionen för medicinska vetenskaper,Centre for Assessment of Medical Technology in Örebro, Region Örebro County, Örebro, Sweden; Department of Radiology, Örebro University Hospital, Örebro, Sweden (författare)

Temperature measurements with a temporal scanner : systematic review and meta-analysis

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • 2016-03-31
  • London, United Kingdom :BMJ Group,2016
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:oru-49633
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-49633URI
  • https://doi.org/10.1136/bmjopen-2015-009509DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:for swepub-publicationtype

Anmärkningar

  • Objectives: Systematic review and meta-analysis on the diagnostic accuracy of temporal artery thermometers (TAT).Design: Systematic review and meta-analysis. The index test consisted of temperature measurement with TAT. The reference test consisted of an estimation of core temperature.Participants: Clinical patients as well as healthy participants, with or without fever.Interventions: Literature search in PubMed, Embase, Cinahl and Web of Science. Three reviewers selected articles for full-text reading after which a further selection was made. Risk of bias was assessed with QUADAS-2. Pooled difference and limits of agreement (LoA) were estimated with an inverse variance weighted approach. Subgroup and sensitivity analyses were performed. Sensitivity and specificity were estimated using hierarchical models. Quality of evidence was assessed according to the GRADE system.Primary and secondary outcome measures: The primary outcome was measurement accuracy expressed as mean difference ±95% LoA. A secondary outcome was sensitivity and specificity to detect fever. If tympanic thermometers were assessed in the same population as TAT, these results were recorded as well.Results: 37 articles comprising 5026 participants were selected. Pooled difference was -0.19°C (95% LoA -1.16 to 0.77°C), with moderate quality of evidence. Pooled sensitivity was 0.72 (95% CI 0.61 to 0.81) with a specificity of 0.94 (95% CI 0.87 to 0.97). The subgroup analysis revealed a trend towards underestimation of the temperature for febrile patients. There was a large heterogeneity among included studies with wide LoA which reduced the quality of evidence.Conclusions: TAT is not sufficiently accurate to replace one of the reference methods such as rectal, bladder or more invasive temperature measurement methods. The results are, however, similar to those with tympanic thermometers, both in our meta-analysis and when compared with others. Thus, it seems that TAT could replace tympanic thermometers with the caveat that both methods are inaccurate.Trial registration number: CRD42014008832.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Udumyan, Ruzan,1971-Örebro universitet,Institutionen för medicinska vetenskaper,Örebro University Hospital, Örebro, Sweden,Clinical Epidemiology and Biostatistics(Swepub:oru)run (författare)
  • Lohse, GeorgCentre for Assessment of Medical Technology in Örebro, Region Örebro County, Örebro, Sweden; Örebro Rehab Center, Örebro, Sweden (författare)
  • Nilsagård, Ylva,1964-Örebro universitet,Institutionen för hälsovetenskaper,Centre for Assessment of Medical Technology in Örebro, Region Örebro County, Örebro, Sweden; Department of Medicine, Örebro University Hospital, Örebro, Sweden(Swepub:oru)ynd (författare)
  • Örebro universitetInstitutionen för medicinska vetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:BMJ OpenLondon, United Kingdom : BMJ Group6:32044-6055

Internetlänk

Hitta via bibliotek

  • BMJ Open (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Geijer, Håkan, 1 ...
Udumyan, Ruzan, ...
Lohse, Georg
Nilsagård, Ylva, ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Allmänmedicin
Artiklar i publikationen
BMJ Open
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy