SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:su-225734"
 

Sökning: onr:"swepub:oai:DiVA.org:su-225734" > Range shifter contr...

  • Romero-Expósito, MaiteThe Skandion Clinic Uppsala Sweden;Oncology Pathology Department Karolinska Institutet Solna Sweden (författare)

Range shifter contribution to neutron exposure of patients undergoing proton pencil beam scanning

  • Artikel/kapitelEngelska2023

Förlag, utgivningsår, omfång ...

  • 2023
  • 2023
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:su-225734
  • https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-225734URI
  • https://doi.org/10.1002/mp.16897DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:154423279URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-518623URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background: Superficial targets require the use of the lowest energies within the available energy range in proton pencil-beam scanning (PBS) technique. However, the lower efficiency of the energy selection system at these energies and the requirement of a greater number of layers may represent disadvantages for this approach. The alternative is to use a range shifter (RS) at nozzle exit. However, one of the concerns of using this beamline element is that it becomes an additional source of neutrons that could irradiate organs situated far from the target.Purpose: The purpose of this study is to assess the increase in neutron dose due to the RS in proton PBS technique. Additionally, an analytical model for the neutron production is tested.Methods: Two clinical plans, designed to achieve identical target coverage, were created for an anthropomorphic phantom. These plans consisted of a lateral field delivering an absorbed dose of 60 Gy (RBE) to the target. One of the plans employed the RS. The MCNP code was used to simulate the plans, evaluating the distribution of neutron dose equivalent (Hn) and the equivalent dose in organ. In the plan with the RS plan, neutron production from both the patient and the RS were assessed separately. Hn values were also fitted versus the distance to field edge using a Gaussian function.Results: Hn per prescription dose, in the plan using the RS, ranged between 1.4 and 3.7 mSv/Gy at the field edge, whereas doses at 40 cm from the edge ranged from 9.9 to 32 μSv/Gy. These values are 1.2 to 10 times higher compared to those obtained without the RS. Both this factor and the contribution of neutrons originating from the RS increases with the distance from field edge. A triple-Gaussian function was able to reproduce the equivalent dose in organs within a factor of 2, although underestimating the values.Conclusions: The dose deposited in the patient by the neutrons originating from the RS predominantly affects areas away from the target (beyond approximately 25 cm from field edge), resulting in a neutron dose equivalent of the order of mSv. This indicates an overall low neutron contribution from the use of RS in PBS.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Liszka, MalgorzataThe Skandion Clinic Uppsala Sweden (författare)
  • Christou, AthanasiaThe Skandion Clinic Uppsala Sweden (författare)
  • Toma-Daşu, Iuliana,1972-Stockholms universitet,Fysikum,Oncology Pathology Department Karolinska Institutet Solna Sweden;Medical Radiation Physics Stockholm University Stockholm Sweden(Swepub:su)iuda0736 (författare)
  • Dasu, AlexandruThe Skandion Clinic Uppsala Sweden;Medical Radiation Sciences, Department of Immunology, Genetics and Pathology Uppsala University Uppsala Sweden(Swepub:uu)aleda511 (författare)
  • The Skandion Clinic Uppsala Sweden;Oncology Pathology Department Karolinska Institutet Solna SwedenThe Skandion Clinic Uppsala Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical physics (Lancaster)0094-2405
  • Ingår i:Medical physics2473-4209

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy