SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-153644"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-153644" > Concurrent validity...

Concurrent validity of an isokinetic lift test used for admission to the Swedish Armed Forces

Bohman, Tony (författare)
Karolinska Institutet,Karolinska institutet
Tegern, Matthias (författare)
Karolinska Institutet,Umeå universitet,Institutionen för samhällsmedicin och rehabilitering,Department of Neurobiology, Care Sciences and Society, Division of Physiotherapy, Karolinska Institutet, Stockholm, Sweden
Halvarsson, Alexandra (författare)
Karolinska Institutet
visa fler...
Broman, Lisbet (författare)
Karolinska Institutet
Larsson, Helena (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2018-11-06
2018
Engelska.
Ingår i: PLOS ONE. - : Public Library of Science. - 1932-6203. ; 13:11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to assess the concurrent validity of the IsoKai isokinetic lift test peak force (IsoKai(Peak))1 in comparison to a submaximal 5-1ORM deadlift test (5-10RM(DL)), and to develop an equation for converting the IsoKai(Peak) in Newton (N) to an estimated 1 RM (1 RMest) deadlift load in kilograms (kg). The participants included 28 males and 16 female employees in the Swedish Armed Forces (20-59 years). Each participant conducted the IsoKai lift test, followed by the 5-1ORM(DL) test at one occasion. The Pearson's correlation coefficient, with a 95% confidence interval was calculated to evaluate the validity between the IsoKai(peak) and the 1 RMest deadlift load derived from the 5-10RM(DL) test. Univariate and multivariable linear regressions were used to derive the equation for calculating the 1 RMest deadlift load based on the IsoKai(Peak)- The IsoKai(p)(eak) showed good- to-excellent correlation with the 1 RMest deadlift weight with a correlation coefficient of 0.84 (0.72-0.91) for the total sample, and 0.65 (0.37-0.83) and 0.81 (0.53-0.93) in males and females, respectively. The final equation, 1 RMest deadlift weight (kg) = -51.63 + (0.08 x IsoKai(Peak))1+ (2.28 x BMI), explained 72% (adjusted R-2 = 0.72) of the total variance in the 1 RMest, and had a standard error of the estimate (SEE) of 16.57 kg. In conclusion, the IsoKai isokinetic lift test could be considered a highly valid measure of maximal dynamic muscular strength in comparison to the 5-10RM(DL). The equation can be used to convert the IsoKai lift test (N) results to an 1 RMest deadlift load (kg), but with consideration of the relative large SEE.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy