SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:umu-182760"
 

Sökning: onr:"swepub:oai:DiVA.org:umu-182760" > The importance of i...

The importance of inertial measurement unit placement in assessing upper limb motion

Höglund, Gustav (författare)
Umeå universitet,Radiofysik
Grip, Helena (författare)
Umeå universitet,Radiofysik
Öhberg, Fredrik, 1969- (författare)
Umeå universitet,Radiofysik
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Medical Engineering and Physics. - : Elsevier. - 1350-4533 .- 1873-4030. ; 92, s. 1-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Motion analysis using inertial measurement units (IMU) has emerged as an alternative to optical motion capture. However, the validity and reliability of upper limb measurements varies significantly between studies. The objective of this study was to determine how sensor placement affects kinematic output in the assessment of motion of the arm, shoulder, and scapula. IMUs were placed proximally/distally on arms, and medially/laterally on the scapula, in a group of eleven healthy participants, while performing nine different motion tasks. Linear regressions and mixed models analysed how these different sensor placements affected the estimated joint motion by establishing the linear relationship between sensors placed on the same body segment. The placement of sensors affected the measured kinematic output considerably, most prominent affect was seen for sensor placement on scapula during flexion and abduction, and on forearm during pronation/supination. The slope of the linear regression lines was 2.5 during flexion, 2.7 during abduction, and 1.8 for forearm pronation/supination. The results of this study suggest that the forearm sensor should be placed on the dorsal side of the forearm, at the distal end; the upper arm sensor should be placed laterally, on the distal part of the arm; and the sensor on the scapula should be placed cranially, along the spine of scapula.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Forearm
Healthy induviduals
Inertial measurement unit
Measurement protocol
Motion analysis
Scapula
Sensor placement
Upper arm

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Höglund, Gustav
Grip, Helena
Öhberg, Fredrik, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Medical Engineer ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy