Sökning: onr:"swepub:oai:DiVA.org:umu-31421" >
Neurological and ge...
Neurological and general outcome in low-risk coronary artery bypass patients using heparin coated circuits
-
- Svenmarker, S. (författare)
- Umeå universitet,Kirurgi
-
- Sandström, E. (författare)
- Umeå universitet,Anestesiologi och intensivvård
-
Karlsson, T. (författare)
-
visa fler...
-
- Häggmark, S. (författare)
- Umeå universitet,Anestesiologi och intensivvård
-
- Jansson, E. (författare)
- Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap
-
- Appelblad, M. (författare)
- Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap
-
- Lindholm, R. (författare)
- Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap
-
- Åberg, T. (författare)
- Umeå universitet,Kirurgi
-
visa färre...
-
(creator_code:org_t)
- Oxford : Oxford University Press, 2001
- 2001
- Engelska.
-
Ingår i: European Journal of Cardio-Thoracic Surgery. - Oxford : Oxford University Press. - 1010-7940 .- 1873-734X. ; 19:1, s. 47-53
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: The clinical significance of heparin coating in cardiopulmonary bypass has previously been investigated. However, few studies have addressed the possible influence on brain function and memory disturbances. Methods: Three hundred low-risk patients exposed to coronary bypass surgery were randomised into three groups according to type of heparin coating: Carmeda Bioactive Surface, Baxter Duraflo II and a control group. Outcome was determined from a number of clinically oriented parameters, including a detailed registry of postoperative deviations from the normal postoperative course. Brain damage was assessed through S100 release and memory tests, including a questionnaire follow-up. Results: Clinical outcome was similar for all groups. Blood loss (Duraflo only), transfusion requirements and postoperative creatinine elevation were reduced in the heparin-coated groups. A lower incidence of atrial fibrillation was noted in the Duraflo group. Heparin coating did not uniformly attenuate the release of S100 or the degree of memory impairment. Conclusions: Cardiopulmonary bypass (CPB) with heparin coating and a reduced dose of heparin seems to be safe. Clinical outcome and neurological injury seem not to be associated with type of heparin coating used for CPB. However, blood loss and transfusion requirements may be reduced.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- Amnesia/etiology
- Blood Loss
- Surgical/physiopathology
- Blood Transfusion
- Brain Damage
- Chronic/etiology
- Cardiopulmonary Bypass/*instrumentation
- *Coated Materials
- Biocompatible
- Coronary Artery Bypass/*instrumentation
- Female
- *Heparin
- Humans
- Male
- Middle Aged
- *Neurologic Examination
- Neuropsychological Tests
- Postoperative Complications/*etiology
- Prospective Studies
- Risk Factors
- S100 Proteins/blood
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas