SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-129498"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-129498" > Three-point Dixon m...

  • Berglund, JohanUppsala universitet,Enheten för radiologi (författare)

Three-point Dixon method enables whole-body water and fat imaging of obese subjects

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • Wiley,2010
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-129498
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-129498URI
  • https://doi.org/10.1002/mrm.22385DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Dixon imaging techniques derive chemical shift-separated water and fat images, enabling the quantification of fat content and forming an alternative to fat suppression. Whole-body Dixon imaging is of interest in studies of obesity and the metabolic syndrome, and possibly in oncology. A three-point Dixon method is proposed where two solutions are found analytically in each voxel. The true solution is identified by a multiseed three-dimensional region-growing scheme with a dynamic path, allowing confident regions to be solved before unconfident regions, such as background noise. 2 pi-Phase unwrapping is not required. Whole-body datasets (256 x 184 x 252 voxels) were collected from 39 subjects (body mass index 19.8-45.4 kg/m(2)), in a mean scan time of 5 min 15 sec. Water and fat images were reconstructed offline, using the proposed method and two reference methods. The resulting images were subjectively graded on a four-grade scale by two radiologists, blinded to the method used. The proposed method was found superior to the reference methods. It exclusively received the two highest grades, implying that only mild reconstruction failures were found. The computation time for a whole-body dataset was 1 min 51.5 sec +/- 3.0 sec. It was concluded that whole-body water and fat imaging is feasible even for obese subjects, using the proposed method.

Ämnesord och genrebeteckningar

  • three-point Dixon
  • whole-body MRI
  • water and fat separation
  • chemical shift imaging
  • fat suppression
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Johansson, LarsUppsala universitet,Enheten för radiologi(Swepub:uu)larsjoha (författare)
  • Ahlström, HåkanUppsala universitet,Enheten för radiologi(Swepub:uu)hakanahl (författare)
  • Kullberg, JoelUppsala universitet,Enheten för radiologi(Swepub:uu)jokul377 (författare)
  • Uppsala universitetEnheten för radiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Magnetic Resonance in Medicine: Wiley63:6, s. 1659-16680740-31941522-2594

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy