100a Berger, P.4 aut
2451 0a Validation of the Simulator for Testing and Rating Endovascular SkillS (STRESS)-machine in a setting of competence testing
264 1c 2010
338 a print2 rdacarrier
520 a AIM: Endovascular skills are an integral part of modern-day vascular surgery. The STRESS machine has been developed to test these skills in vascular surgeons. This study aims to define an optimal pass/fail cutoff value for the STRESS test score. METHODS: The STRESS machine consists of a dry glass model of the abdominal aorta and its tributaries with various stenotic lesions, elongations, and tortuosities. A camera and computer software are used to simulate plain fluoroscopy-mode. The test subjects are given two assignments after which two reviewers use a combination of the ICEPS and MRS to produce the final total score; 43 subjects were tested. According to previous endovascular experience, subjects were classified into four groups: novice-low (no experience, less than 11 performed procedures, less than 50 assisted procedures), novice-high (11-25 performed procedures, more than 50 assisted procedures), intermediate (1-10 performed and >11-25 assisted procedures, 11-25 performed and >1-10 assisted procedures or 25-50 performed procedures) and advanced (more than 50 performed procedures). RESULTS: Test-score and noted experience showed a correlation of 0.794. All intermediate and advanced test subjects scored more than 50 points compared to 4 out of 15 novices. CONCLUSION: We demonstrated that it is possible to determine an optimal cut-off value for competence testing with the STRESS machine.
653 a MEDICINE
653 a MEDICIN
700a Willems, M. C.4 aut
700a Van Der Vliet, J. A.4 aut
700a Schultze Kool, L. J.4 aut
700a Bergqvist, Davidu Uppsala universitet,Kärlkirurgi4 aut0 (Swepub:uu)daviberg
700a Blankensteijn, J. D.4 aut
710a Uppsala universitetb Kärlkirurgi4 org
773t Journal of Cardiovascular Surgeryg 51:2, s. 253-256q 51:2<253-256x 0021-9509x 1827-191X
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-131014

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy