Sökning: onr:"swepub:oai:DiVA.org:uu-237311" >
Quantitative Assess...
Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [O-15]H2O PET Imaging
-
Danad, Ibrahim (författare)
-
Uusitalo, Valtteri (författare)
-
- Kero, Tanja (författare)
- Uppsala universitet,Enheten för nuklearmedicin och PET
-
visa fler...
-
Saraste, Antti (författare)
-
- Raijmakers, Pieter G. (författare)
- Uppsala universitet,Enheten för nuklearmedicin och PET
-
- Lammertsma, Adriaan A. (författare)
- Uppsala universitet,Enheten för nuklearmedicin och PET
-
Heymans, Martijn W. (författare)
-
Kajander, Sami A. (författare)
-
Pietilae, Mikko (författare)
-
- James, Stefan K. (författare)
- Uppsala universitet,Kardiologi,Uppsala kliniska forskningscentrum (UCR)
-
- Sörensen, Jens (författare)
- Uppsala universitet,Klinisk fysiologi,Enheten för nuklearmedicin och PET
-
Knaapen, Paul (författare)
-
Knuuti, Juhani (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2014
- 2014
- Engelska.
-
Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 64:14, s. 1464-1475
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD. OBJECTIVES The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [O-15]H2O positron emission tomography (PET). METHODS A total of 330 patients underwent both quantitative [O-15]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve <= 0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive. RESULTS Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 +/- 0.25 and 0.92 +/- 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 +/- 1.04 ml/min/g and 1.73 +/- 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET. CONCLUSIONS Quantitative MBF measurements with the use of [O-15]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- myocardial blood flow
- myocardial flow reserve
- receiver-operator characteristic curve
- sensitivity
- specificity
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Danad, Ibrahim
-
Uusitalo, Valtte ...
-
Kero, Tanja
-
Saraste, Antti
-
Raijmakers, Piet ...
-
Lammertsma, Adri ...
-
visa fler...
-
Heymans, Martijn ...
-
Kajander, Sami A ...
-
Pietilae, Mikko
-
James, Stefan K.
-
Sörensen, Jens
-
Knaapen, Paul
-
Knuuti, Juhani
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Kardiologi
- Artiklar i publikationen
-
Journal of the A ...
- Av lärosätet
-
Uppsala universitet