SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-2605"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-2605" > Analytical Aspects ...

Analytical Aspects of Atmospheric Pressure Ionisation in Mass Spectrometry

Bökman, C. Fredrik (författare)
Uppsala universitet,Avdelningen för analytisk kemi
Pinkston, J. David (opponent)
 (creator_code:org_t)
ISBN 9155453961
Uppsala : Acta Universitatis Upsaliensis, 2002
Engelska 48 s.
Serie: Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, 1104-232X ; 748
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The actual signal recorded with an analytical instrument is not always a true reflection of the analysed sample. In this thesis a further insight of the atmospheric pressure ionisation processes electrospray (ESI) and atmospheric pressure chemical ionisation (APCI) has been endeavoured, to provide a deeper understanding of and ways to minimize this bias.A response model for ESI has been modified and used to study the influence of solvent composition on the observed mass spectrometric signal. The response model divides the response into an analyte partitioning coefficient and an instrumental response factor. A number of experimental parameters influencing the response were investigated including spray position relative to the orifice, spray potential, nebulizer and curtain gas flow rates, ionic strength and organic content of the sprayed solution. The history of the generated droplets turned out to be of significant importance to both the partitioning coefficients and the instrumental response factor. Furthermore, it was found that the total ionic strength and not only the electrolyte concentration will influence the instrumental response factor.In addition, based on the importance of hydrophobicity and electrophoretic mobility, a model was proposed for the ion distribution within the electrosprayed droplets.The coupling of an electrochemical (EC) cell to a mass spectrometric (MS) system has been evaluated. The coupling of the EC cell to the MS was made to decouple the cell from the high voltage circuit of the ESI. The feasibility for analyte ionisation, sample pre-concentration and solvent exchange as well as studying redox reaction products was shown.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Analytical chemistry
Analytisk kemi
Analytical chemistry
Analytisk kemi
Analytical Chemistry
analytisk kemi

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bökman, C. Fredr ...
Pinkston, J. Dav ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Delar i serien
Comprehensive Su ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy