SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-319488"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-319488" > Evaluation of ECG-g...

  • Hansson, Nils Henrik (författare)

Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • 2016-04-19
  • Springer Science and Business Media LLC,2016
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-319488
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-319488URI
  • https://doi.org/10.1007/s12350-015-0331-0DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • BACKGROUND: Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET.METHODS: Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE.RESULTS: LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P < .001 for all), but were underestimated by PET (P < .001 for all except ESV P = .79). PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P < .001, bias -3 ± 21%, P = .56). PET-based MEE bias was strongly associated with LV wall thickness.CONCLUSIONS: Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

Ämnesord och genrebeteckningar

  • Myocardial external efficiency
  • PET imaging
  • magnetic resonance imaging
  • metabolism: PET

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Tolbod, Lars (författare)
  • Harms, Johannes (författare)
  • Wiggers, Henrik (författare)
  • Kim, Won Yong (författare)
  • Hansen, Esben (författare)
  • Zaremba, Tomas (författare)
  • Frøkiær, Jørgen (författare)
  • Jakobsen, Steen (författare)
  • Sörensen, JensUppsala universitet,Radiologi(Swepub:uu)jenssore (författare)
  • Uppsala universitetRadiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Nuclear Cardiology: Springer Science and Business Media LLC23:4, s. 670-91071-35811532-6551

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy