SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-343469"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-343469" > The 99th percentile...

  • Greiser, Anne (författare)

The 99th percentile and imprecision of point-of-care cardiac troponin I in comparison to central laboratory tests in a large reference population

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-343469
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-343469URI
  • https://doi.org/10.1016/j.clinbiochem.2017.08.006DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:137102739URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • OBJECTIVES: Determination of cardiac troponin (cTn) is central in the emergency department (ED) for the diagnosis of myocardial infarction. In view of adverse effects of long waiting time on patient outcome, implementation of point-of-care-testing (POCT) is suggested if the turn-around-time is longer than 60min. The present study aimed to determine the 99th percentile and imprecision of two POCT in a healthy population measuring cTnI and cTnT and compare these analytical characteristics against three central laboratory test (CLT) for cTnI.DESIGN & METHODS: CTnI and cTnT were determined in parallel by means of the AQT90 FLEX analyzer in about 2250 plasma samples from individuals with known health status. Results were compared to previously determined performance data of three CLT.RESULTS: The 99th percentile of cTnI in the POCT was determined at 19ng/L, the lowest concentration with an imprecision of 10% was reached at 22ng/L while an imprecision of 20% was reached at 13ng/L. Age, sex, or physical activity did not affect the 99th percentile of cTnI. Compared to CLT the AQT90 cTnI POCT the analytical performance was equivalent. The cTnT POCT could not be assessed due a considerable number of high values and an inadequate imprecision profile.CONCLUSION: While the cTnI POCT showed analytical performance comparable to CLT, the results of the cTnT assay on the same device did not suffice to determine a reliable 99th percentile. The present evaluation supports the usage of the cTnI POCT, but application of the cTnT POCT needs further evaluation.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Winter, Theresa (författare)
  • Mahfoud, Hala (författare)
  • Kallner, AndersKarolinska Institutet (författare)
  • Ittermann, Till (författare)
  • Masuch, Annette (författare)
  • Lubenow, NorbertUppsala universitet,Klinisk immunologi(Swepub:uu)norlu522 (författare)
  • Kohlmann, Thomas (författare)
  • Greinacher, Andreas (författare)
  • Nauck, Matthias (författare)
  • Petersmann, Astrid (författare)
  • Karolinska InstitutetKlinisk immunologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Biochemistry: Elsevier BV50:18, s. 1198-12020009-91201873-2933

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy