SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-389614"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-389614" > Preoperative aortic...

Preoperative aortic annulus size assessment by transthoracic echocardiography compared to the size of surgically implanted aortic prostheses

Ingimarsdottir, I. J. (författare)
Uppsala Univ Hosp, Dept Cardiol, Uppsala, Sweden
Johansson Hellgren, Laila (författare)
Uppsala universitet,Thoraxkirurgi
Flachskampf, Frank A., 1957- (författare)
Uppsala universitet,Klinisk fysiologi,Uppsala Univ Hosp, Uppsala, Sweden
 (creator_code:org_t)
2019
2019
Engelska.
Ingår i: ECHO RESEARCH AND PRACTICE. - 2055-0464. ; 6:2, s. 37-41
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: The aortic annulus diameter measured by transthoracic echocardiography yields lower values than by computed tomography, and echo-based selection of transcatheter aortic valve prosthesis size has been implied to result in more frequent paravalvular leakage. We investigated the relation of preoperative annulus diameter by echo with the ring size of the aortic prosthesis chosen by direct assessment during open-heart aortic valve replacement.Methods: Preoperative annulus diameter by echo (from parasternal long-axis cross-sections of the left ventricular outflow tract and aortic valve) and implanted prosthetic diameter (tissue annulus diameter, determined intraoperatively using a sizing instrument) were compared retrospectively in 285 consecutive patients undergoing open-heart aortic valve replacement.Results: A total of 285 prostheses (240 biologic and 45 mechanical) were implanted, with prosthetic diameter ranging between 19 and 27 mm. There was a significant linear correlation (P < 0.0001) with r = 0.51, between preoperative annulus diameter by echo (mean 21.8 +/- 2.8 mm) and prosthetic diameter (22.9 +/- 1.7 mm). Preoperative annulus diameter of patients receiving prostheses no. 21, 23 and 25 mm aortic prostheses (the most frequent prosthesis sizes) were significantly different (P < 0.001) from each other. On average, preoperative annulus diameter by echo underestimated prosthetic diameter by a bias of 1.07 mm.Conclusion: Our data confirm that preoperative echo assessment of the aortic valve may slightly underestimates the optimal surgical prosthesis diameter for the aortic valve annulus.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

aortic valve
aortic valve replacement
prosthetic valve
echocardiography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ingimarsdottir, ...
Johansson Hellgr ...
Flachskampf, Fra ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
ECHO RESEARCH AN ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy