Sökning: onr:"swepub:oai:DiVA.org:uu-454122" >
Ga-68-DOTATOC-PET/M...
Ga-68-DOTATOC-PET/MRI and C-11-5-HTP-PET/MRI are superior to Ga-68-DOTATOC-PET/CT for neuroendocrine tumour imaging
-
- Jawlakh, Hiba (författare)
- Uppsala universitet,Radiologi
-
- Velikyan, Irina, 1966- (författare)
- Uppsala universitet,Radiologi
-
- Welin, Staffan (författare)
- Uppsala universitet,Onkologisk endokrinologi
-
visa fler...
-
- Sundin, Anders, 1954- (författare)
- Uppsala universitet,Radiologi
-
visa färre...
-
(creator_code:org_t)
- 2021-05-28
- 2021
- Engelska.
-
Ingår i: Journal of neuroendocrinology. - : John Wiley & Sons. - 0953-8194 .- 1365-2826. ; 33:6
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
https://onlinelibrar...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The present study aimed to assess gadoxetate disodium contrast-enhanced (CE) positron emission tomography (PET)/magnetic resonance imaging (MRI) with Ga-68-DOTATOC and C-11-5-Hydroxy-tryptophan (C-11-5-HTP) in comparison with iodine CE Ga-68-DOTATOC-PET/computed tomography (CT) for neuroendocrine tumour imaging. Detection rate and reader's confidence were evaluated for each separate image volume: CE-CT, CE-MRI including diffusion-weighted imaging, Ga-68-DOTATOC-PET performed at PET/CT, Ga-68-DOTATOC-PET performed at PET/MRI and C-11-5-HTP-PET, and for the three combined hybrid examinations Ga-68-DOTATOC-PET/MRI, C-11-5-HTP-PET/MRI and Ga-68-DOTATOC-PET/CT. In 11 patients, 255 lesions were depicted. Ga-68-DOTATOC-PET performed at PET/MRI depicted 72.5%, Ga-68-DOTATOC-PET performed at PET/CT depicted 62.7%, C-11-5-HTP-PET depicted 68.2% and CE-CT depicted 53% of lesions. Ga-68-DOTATOC-PET performed at PET/MRI (P < 0.001) and PET/CT (P = 0.02), C-11-5-HTP-PET (P < 0.001) and MRI (P < 0.001) were superior to CT. Ga-68-DOTATOC-PET/MRI and C-11-5-HTP-PET/MRI detected 92.5% and 92% of lesions, respectively, and both outperformed Ga-68-DOTATOC-PET/CT (65%) (P < 0.001). For liver metastasis imaging, MRI alone was unsurpassed (P < 0.01) and Ga-68-DOTATOC-PET/MRI and C-11-5-HTP-PET/MRI outperformed Ga-68-DOTATOC-PET/CT (P < 0.001). For lymph node metastasis diagnosis, Ga-68-DOTATOC-PET performed at PET/MRI and PET/CT and C-11-5-HTP-PET detected 94%, 94% and 94% of lesions, respectively, and outperformed MRI and CE-CT alone (P < 0.001). For bone metastasis imaging, Ga-68-DOTATOC-PET performed at PET/MRI and PET/CT and C-11-5-HTP-PET performed equally well (P = 0.05) and better than MRI. Reader's confidence was better for Ga-68-DOTATOC-PET/MRI and C-11-5-HTP-PET/MRI than for Ga-68-DOTATOC-PET/CT. The tumour maximum standardised uptake value and tumour-to-liver ratio were both approximately twice as high as for Ga-68-DOTATOC than for C-11-5-HTP. Ga-68-DOTATOC-PET/MRI and C-11-5-HTP-PET/MRI provided the highest detection rates and reader's confidence and were both superior to Ga-68-DOTATOC-PET/CT, mainly because of the MRI component. The imaging contrast with Ga-68-DOTATOC was superior to that of C-11-5-HTP.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- C-11-5-HTP
- Ga-68-DOTATOC
- detection rate
- neuroendocrine tumour
- PET/CT
- PET/MRI
- SUVmax
- tumour-to-background ratio
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas