SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-487237"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-487237" > Primary hyperparath...

  • Sandqvist, PatriciaKarolinska Institutet (författare)

Primary hyperparathyroidism, a machine learning approach to identify multiglandular disease in patients with a single adenoma found at preoperative Sestamibi-SPECT/CT

  • Artikel/kapitelEngelska2022

Förlag, utgivningsår, omfång ...

  • Bioscientifica,2022
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-487237
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-487237URI
  • https://doi.org/10.1530/EJE-22-0206DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:150789933URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Objective: Successful preoperative image localisation of all parathyroid adenomas (PTA) in patients with primary hyperparathyroidism (pHPT) and multiglandular disease (MGD) remains challenging. We investigate whether a machine learning classifier (MLC) could predict the presence of overlooked PTA at preoperative localisation with Tc-99m-Sestamibi-SPECT/CT in MGD patients.Design: This study is a retrospective study from a single tertiary referral hospital initially including 349 patients with biochemically confirmed pHPT and cured after surgical parathyroidectomy.Methods: A classification ensemble of decision trees with Bayesian hyperparameter optimisation and five-fold cross-validation was trained with six predictor variables: the preoperative plasma concentrations of parathyroid hormone, total calcium and thyroid-stimulating hormone, the serum concentration of ionised calcium, the 24-h urine calcium and the histopathological weight of the localised PTA at imaging. Two response classes were defined: patients with single-gland disease (SGD) correctly localised at imaging and MGD patients in whom only one PTA was localised on imaging. The data set was split into 70% for training and 30% for testing. The MLC was also tested on a subset of the original data based on CT image-derived PTA weights.Results: The MLC achieved an overall accuracy at validation of 90% with an area under the cross-validation receiver operating characteristic curve of 0.9. On test data, the MLC reached a 72% true-positive prediction rate for MGD patients and a misclassification rate of 6% for SGD patients. Similar results were obtained in the testing set with image-derived PTA weight.Conclusions: Artificial intelligence can aid in identifying patients with MGD for whom Tc-99m-Sestamibi-SPECT/CT failed to visualise all PTAs.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Sundin, Anders,1954-Uppsala universitet,Radiologi(Swepub:uu)anderssu (författare)
  • Nilsson, Inga-LenaKarolinska Institutet (författare)
  • Gryback, PerKarolinska Institutet (författare)
  • Sanchez-Crespo, AlejandroKarolinska Institutet (författare)
  • Karolinska InstitutetRadiologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Journal of Endocrinology: Bioscientifica187:2, s. 257-2630804-46431479-683X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy