Interspinous Process Implants Causes Wear of the Spinous Processes in Patients Treated for Spinal Stenosis—An Experimental Biomechanical Study with Comparison to Clinical Cases

Baranto, Adad, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Hagelberg, Christian, 1974 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Hvannberg, Jonas (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa fler...
Ekström, Lars, 1959 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Halldin, Klas, 1967 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Brisby, Helena, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
Scientific Research Publishing, Inc. 2016
2016
Engelska.
Ingår i: Open Journal of Orthopedics. - : Scientific Research Publishing, Inc.. - 2164-3008 .- 2164-3016. ; :6, s. 201-210
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • There are few biomechanical studies on Interspinous Process Implants (IPD); however none investigate the amount of wear on spinous processes. Therefore the objective of the present study was to investigate the effect of repetitive loading of the IPD Aperius on the spinous processes in a biomechanical porcine model. For comparison, three patients treated surgically with the same device have been followed for one to two years clinically and with image analyses (X-rays, MRI, CT-scans). Four lumbar spines from 6 months old porcine were divided into seven segments, which received IPD. The segments were exposed to 20,000 cyclical loads. Afterwards the deformation (wear) of the segments was registered. The wear of the spinous processes was measured in mm on a following CT-scan. Additionally, the wear of the ex-vivo was compared to that of the spinous processes investigated by CT-scans or X-ray in three patients treated surgically with the same interspinous implant. The mean maximal deformation of porcine specimens was 1.79 mm (SD 0.25) with the largest deformation occurring in the first quarter of the loading (<5000 cycles). The mean wear of the spinous processes after loading was 6.57 mm. A similar level of wear (mean 12.7 mm) of the spinous processes was detected in the patients. The Aperius IPD creates significant wear on the spinous processes in an experimental biomechanical study. Similar wear of the spinous pro-

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

Porcine
Interspinous Process Device
Cyclic Loading
Wear
Degenerative Lumbar Spinal Canal Stenos
Aperius PercLID

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy