SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/273173"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/273173" > Interleukin-6 measu...

Interleukin-6 measured using the automated electrochemiluminescence immunoassay method for the identification of intra-amniotic inflammation in preterm prelabor rupture of membranes.

Musilova, Ivana (författare)
Andrys, Ctirad (författare)
Holeckova, Magdalena (författare)
visa fler...
Kolarova, Veronika (författare)
Pliskova, Lenka (författare)
Drahosova, Marcela (författare)
Bolehovska, Radka (författare)
Pilka, Radovan (författare)
Huml, Karel (författare)
Cobo, Teresa (författare)
Jacobsson, Bo, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Kacerovsky, Marian (författare)
visa färre...
 (creator_code:org_t)
2018-12-17
2020
Engelska.
Ingår i: The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. - : Informa UK Limited. - 1476-4954. ; 33:11, s. 1919-1926
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We aimed to compare the amniotic fluid interleukin (IL)-6 concentrations measured using the automated electrochemiluminescence immunoassay method and ELISA, and to establish an IL-6 concentration cut-off value for intra-amniotic inflammation (IAI) in preterm prelabor rupture of membranes (PPROM), which can be used in the automated electrochemiluminescence immunoassay method.A total of 120 women with PPROM were included in this study. Amniotic fluid samples were obtained via transabdominal amniocentesis. IL-6 concentrations were assessed using both the automated electrochemiluminescence immunoassay method and ELISA, the current gold standard. IAI was defined as an amniotic fluid IL-6 concentration of ≥ 2600 pg/mL measured using ELISA.A correlation between both assays was found (Spearman's rho = 0.97; p < 0.0001). Based on the receiver-operating characteristic curve for the identification of IAI (area under the curve = 0.99), a cut-off value of ≥ 3000pg/mL was selected for the automated electrochemiluminescence immunoassay method with a sensitivity of 88%, specificity of 99%, positive predictive value of 97%, negative predictive value of 96%, and likelihood ratio of 76.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy