SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/49242"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/49242" > Effect of peritonea...

Effect of peritoneal dialysis fluid composition on peritoneal area available for exchange in children

Fischbach, M. (författare)
Terzic, J. (författare)
Chauve, S. (författare)
visa fler...
Laugel, V. (författare)
Muller, A. (författare)
Haraldsson, Börje, 1957 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för invärtesmedicin, Avdelningen för njurmedicin,Wallenberglaboratoriet,Institute of Internal Medicine, Dept of Nephrology,Wallenberg Laboratory
visa färre...
 (creator_code:org_t)
2004-03-18
2004
Engelska.
Ingår i: Nephrol Dial Transplant. - : Oxford University Press (OUP). - 0931-0509. ; 19:4, s. 925-32
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Although conventional peritoneal dialysis fluids (PDFs), such as Dianeal, are non-physiological in composition, new PDFs including Physioneal have a more neutral pH, are at least partially buffered with bicarbonate and, most importantly, contain low concentrations of glucose degradation products (GDPs). METHODS: To evaluate the impact of new PDFs in childcare, we performed a comparative crossover study with Dianeal and Physioneal. We examined both intraperitoneal pressure (IPP), which partly reflects pain induction, and the total pore area available for exchange, which indicates the number of capillaries perfused in the peritoneal membrane at any given moment and therefore partly reflects peritoneal dialysis capacity. The IPP was determined after inflow of 1000 ml/m(2) body surface area (BSA) of dialysate (intraperitoneal volume; IPV). The steady-state unrestricted area over diffusion distance (A(0)/ triangle up x, in cm(2)/cm per 1.73 m(2) BSA) was calculated from the three-pore theory. Six children were enrolled in the study. On the first day, two consecutive peritoneal equilibration tests of 90 min each were performed using first Dianeal and then Physioneal. On the second study day, the procedure was repeated with the fluids given in the opposite order. RESULTS: The mean IPP normalized to IPV (ml/m(2)) was significantly higher for Dianeal (9.5 +/- 0.9 cm/1000 ml/m(2)) than for Physioneal (7.9 +/- 1.2 cm/1000 ml/m(2), P < 0.01). The mean A(0)/ triangle up x was 17 +/- 4% larger with Dianeal (36 095 +/- 2009 cm(2)/cm per 1.73 m(2)) than with Physioneal (31 780 +/- 2185 cm(2)/cm per 1.73 m(2), P < 0.001; based on 24 data pairs). CONCLUSIONS: These pilot study results suggest a higher biocompatibility for Physioneal than for Dianeal. Less inflow pain associated with Physioneal induced a lower IPP reflecting enhanced fill volume tolerance, and the lower A(0)/ triangle up x reflected less capillary recruitment. Taken together, these results suggest that the new more biocompatible PDFs will improve peritoneal dialysis therapy, although this conclusion will require verification in extended clinical trials.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy