Sökning: onr:"swepub:oai:gup.ub.gu.se/62956" >
Influence of two di...
Influence of two different perfusion systems on inflammatory response in pediatric heart surgery.
-
- Jensen, Eva (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
-
- Andréasson, Svenerik (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences
-
- Bengtsson, Anders, 1954 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för anestesiologi och intensivvård,Institute of Surgical Sciences, Department of Anaesthesiology and Intensive Care
-
visa fler...
-
- Berggren, Håkan, 1951 (författare)
- Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
-
- Ekroth, Rolf, 1944 (författare)
- Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
-
- Lindholm, Lena (författare)
- Gothenburg University,Göteborgs universitet,Hjärt-kärlinstitutionen,Cardiovascular Institute
-
- Ouchterlony, John (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences
-
visa färre...
-
(creator_code:org_t)
- 2003
- 2003
- Engelska.
-
Ingår i: The Annals of thoracic surgery. - 0003-4975. ; 75:3, s. 919-25
- Relaterad länk:
-
https://gup.ub.gu.se...
Abstract
Ämnesord
Stäng
- BACKGROUND: This study tests the hypothesis that a cardiopulmonary bypass system that combines complete heparin-coating, a centrifugal pump, and a closed circuit in comparison with a conventional system (uncoated system, roller pump, and hard shell venous reservoir) attenuates the inflammatory response in pediatric heart surgery. METHODS: In a prospective randomized controlled clinical study 40 consecutive children weighing 10 kg or less were included and divided into two groups. Concentrations of complement proteins (C3a, sC5b-9, C4d, and Bb), granulocyte degranulation products (polymorphonuclear [PMN] elastase), and proinflammatory cytokines (tumor necrosis factor [TNF]-alpha, interleukin [IL]-6, and IL-8) were measured. RESULTS: C3a and sC5b-9 concentrations were lower (C3a, p < 0.001; sC5b-9, p = 0.01) in the combined (heparin-coated/centrifugal pump/closed reservoir) group, the peak values being 58% and 37% of conventional group values. The Bb- and C4d-fragment values indicated activation of the complement system through the alternative pathway in both groups. PMN elastase concentrations were lower (p = 0.02) in the combined group, the peak values being 43% of conventional group values. There were no significant intergroup differences regarding TNF-alpha, IL-6, or IL-8 concentrations. CONCLUSIONS: The use of a fully heparin-coated system, a centrifugal pump, and a closed circuit during CPB in children (10 kg or less) leads to a lower degree of complement activation and PMN elastase release compared with a conventional system.
Nyckelord
- Adolescent
- Cardiopulmonary Bypass
- instrumentation
- Child
- Child
- Preschool
- Coated Materials
- Biocompatible
- Complement Activation
- immunology
- Equipment Design
- Female
- Heart Defects
- Congenital
- surgery
- Heparin
- Humans
- Infant
- Inflammation Mediators
- blood
- Interleukin-6
- blood
- Interleukin-8
- blood
- Leukocyte Elastase
- blood
- Male
- Postoperative Complications
- immunology
- prevention & control
- Systemic Inflammatory Response Syndrome
- immunology
- prevention & control
- Tumor Necrosis Factor-alpha
- metabolism
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas